background image

6

DESOLDERING PROCEDURE

1. Position suction cup.

2. Hot-air melts solder.

3. IC pops up automatically.

EDIT PROFILE

This option allows you to edit or create a profile. 
First , you must select the profile to edit and then modify the points that make up the profile. 
Each profile is composed of 9 points, each point is formed by three parameters: 
 

1. Time (seconds) 

 

2. Temperature (°C / °F) 

 

3. Flow rate (%)

You can delete the last point of the profile by selecting “-----” in the time parameter. 
It should be taken into account that the regulation range permitted by the station is between 150°C and 
450°C, whereby it is not possible to create temperature ramps between room temperature (Toff) and 
150°C.

The station can store up to 25 temperature profiles.
The first three profiles are edited as an example.

COPY PROFILE

This option allows you to copy a profile. 
You must select the profile source and the destination profile where it will be copied.

DELETE PROFILE

This option will allow you to delete a profile previously selected.

Summary of Contents for TE Series

Page 1: ...TE PRECISION HOT AIR STATION www jbctools com...

Page 2: ...TN9209 3 TN9208 4 TN9080 5 NOZZLE 0930110 SUCTION CUPS 0932330 SUCTIONTUBE T2050 20 T2250 40 TRIPOD POWER CORD These accessories not supplied withTE 2QB TE 1QB TE 9QB stations Protector P2220 32 P2230...

Page 3: ...ay USB connector to PC Update station software Create graphs of the soldering process Manage and monitor parameters via PC Function keys Connectable tools JT T2A JT T1A TE TB Heating element Hot Air s...

Page 4: ...5 seconds Profile 8 Power 70 400 380 80 Selected temperature Current temperature Instant power supplied to heater Selected profile Current temperature Selected flow Graph of selected profile Remaining...

Page 5: ...m version 1 Temp unit Celsius 2 Maximum temp 4500 C 3 Minimum temp T OFF 4 Fix temp 4000 C 5 Max air 100 6 Min air 10 7 Fix air 40 8 Time to stop 120 sec 9 Beep ON 10 Pop up ON 11 Change PIN 1 Station...

Page 6: ...he last point of the profile by selecting in the time parameter It should be taken into account that the regulation range permitted by the station is between 150 C and 450 C whereby it is not possible...

Page 7: ...the heating element set is cold 1 Untighten screw 2 Separate the heating element from the heating set s handle 3 Connect new heating element pushing it s extreme 4 Insert screw to aviod air loss witc...

Page 8: ...NS Temperature selection from room temperature to 450 C 850 F and cool mode can be used to blow air at room temperature Ambient Operating Temperature 10 to 40 C 50 104 F Output Peak Power 300W Air flo...