R-Axy
W-Axy
W-MAT
Code
Description
Details
Read - Adjust
Temperature
+ port + tool
Write - Adjust
Temperature
+ port + tool
Write -
Maximum
Temperature
To get the Tool Adjustment Temperature.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number in
ACCII, for example “RA12” for port 1 and tool TR245.
See page 8 for identifier information.
The JBC device answers with an “A-Axy”.
The Data Field contains the Tool Ajustment
Temperature, expressed in °C.
Sets a temperature offset.
Used when a tool temperature fine-adjustment is
needed.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number in
ACCII, for example “WA12”, for port 1 and tool TR245.
See page 8 for identifier information.
The Data field contains the Adjustment Temperature
for the tool, expresed in °C. The maximum adjustment
temp is +/- 50°C, for example “WA1200012”. The
temperature offset must be done in steps of 1 degree.
Note: In order to send -50 °C, the data will be sent is
“-0050”.
The JBC device answers with an “A-Axy”.
Set the Maximum Temperature selectable with W-STx.
The Data Field contains the Maximum Work
Temperature, expressed in °C
The JBC device responds with an “A-MAT”.