R-MAT
R-MIT
W-MIT
W-Sxy
Read -
Maximum
Temperature
Read - Minimum
temperature
Write - Minimum
temperature
Write - Sleep
Temperature
+ port + tool
To get the Maximum Temperature selectable With
W-STx.
The JBC device responds with an “A-MAT”.
The Data Field contains the Maximum Working
Temperature, expressed in °C.
To get the Minimum Temperature selectable with
W-STx.
The JBC device responds with an “A-MIT”.
The Data Field contains the Minimum Work
Temperature, expressed in °C.
Set the Minimum Temperature selectble with W-STx.
The Data Field contains the Minimum Work
Temperature, expressed in °C.
The JBC device responds with an “A-MIT”
Sets the Sleep Temperature.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number* in
ACCII, for example “WS12”, for port 1 and tool TR245.
See page 8 for identifier information.
The Sleep Temperature must be done in steps of 5
degrees.
The data Field contains the Sleep Temperature for the
tool, expressed in °C.
The JBC device answers with an “A-Sxy”.
Code
Description
Details
14