R-Sxy
Read - Sleep
Temperature
+ port + tool
To get the Sleep Temperature.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number in
ACCII, for example “RS12”, for port 1 and tool TR245.
See page 8 for identifier information.
The JBC device answers with an “A-Sxy”.
The Data Field contains the Sleep Temperature,
expressed in °C.
Code
Description
Details
W-Dxy
R-Dxy
Write - Sleep
Delay
+ port + tool
Read - Sleep
delay
+ port + tool
Sets the Sleep Delay Time.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number* in
ACCII, for example “WD12”, for port 1 and tool TR245.
See page 8 for identifier information.
The data Field contains the delay time, to enter into
sleep since the command W-PSx-00001 is received.
The Sleep Delay must be set in steps of 1 minute with
a range from 0 to 9.
To disable the sleep mode, send “99999”.
The JBC device answers with an “A-Dxy”.
To get the Sleep Delay Time.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number* in
ACCII, for example “RD12”, for port 1 and tool TR245.
See page 8 for identifier information.
The JBC device answers with an “A-Dxy”.
The Data Field contains the current Sleep Delay Time,
expressed in minutes.
If get answered “99999”, the sleep mode is disabled.
15
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm