HANDLING PRECAUTIONS 

Never attempt to move a full or partially full PICOTOPE. 

Never lift by grabbing the aquarium walls. 

Never use cleaners that contain ammonia to clean the glass surfaces. 

Always lift and carry the PICOTOPE from underneath giving support to 

the bottom at all times. 

CHOOSING A LOCATION 

Find a leveled surface that can support the weight of the tank, water, 

and livestock. An average aquarium can weigh 10lbs per gallon once 

filled with water, rock, gravel, and other accessories. 

 

Do not place in direct sunlight to prevent excessive algae growth and 

higher water temperatures. 

FILLING THE TANK 

Always dechlorinate tap water before adding into the aquarium. 

Always fill with room temperature water.  

Rinse Activated Carbon which is located in the rear filter compartment 

under the sink for 30 seconds or until water runs clear. 

Fill the main body of the PICOTOPE until water reaches the bottom of 

the clamp for the light fixture. Once PICOTOPE is filled, plug PICO pow-

erfilter power cord into an approved electrical outlet with a fuse or cir-

cuit breaker.  

Once filter is on, water will enter intake strainer through the filtration 

media and return back into the tank. 

ADDING A HEATER ( not included) 

If you wish to keep tropical (warm water) fish you will need a submersi-

ble heater to maintain optimal water temperatures to simulate their 

natural environment. Most tropical fish will need a temperature range 

between 74-78 F for optimal living conditions. 

 

A heater can be placed in the main body of the PICOTOPE behind 

accessories such as decorations, plants, or rocks.  

We recommend a small 100% submersible 25-50 watt heater if neces-

sary. 

Note: 

Evaporation occurs faster in smaller tanks that have open tops. Please 

check water level regularly to ensure filter is functioning properly

 

Summary of Contents for Picotope

Page 1: ...TRANSWORLD AQUATIC ENTERPRISES INC...

Page 2: ...OF CONTENTS Important Safety Instructions 3 5 Picotope Parts View 6 9 Introduction 10 11 Getting Started 12 Lighting 13 Maintenance Procedures 14 15 Maintenance Log 16 18 Warranty Information 19 Note...

Page 3: ...by the user for each cord con necting an aquarium appliance to a re ceptacle The drip loop is that part of the cord below the level of the recepta cle or the connector if an extension cord is used to...

Page 4: ...all the important notices on the appliance L This Appliance has a polarized plug one blade is wider than the other As a safety feature this plug will fit in a polarized outlet only one way If the plug...

Page 5: ...prevent scratching the aquarium use a damp terrycloth when clean ing Never use algae scrapers scouring pads razor blades glass cleaner or other such abrasives In order to assure proper electrical con...

Page 6: ...6 PARTS EXPLODED VIEW IDENTIFICATION 3 GALLON CURVED GLASS STARTER TANK PARTS EXPLODED VIEW IDENTIFICATION PICO FILTER 0...

Page 7: ...k Only WF 2015 1 Filter Box Cover WF 2015 2 Mechanical Sponge WF 2015 3 Biological Sponge WF 2015 4 Flow Valve WF 2015 5 Intake Tube Elbow WF 2015 6 Filter Box WF 2015 7 Impeller Magnet Assembly WF 20...

Page 8: ...8 PARTS EXPLODED VIEW IDENTIFICATION LAMP FIXTURE...

Page 9: ...2 Lamp Clip CL 609 3 CF Lamp CL 609 4 Lamp Cover CL 609 5 Screws CL 609 6 Telescoping Arms CL 609 7 Spiral Cord CL 609 8 Switch Cover CL 609 9 Switch CL 609 10 Clamp Base CL 609 11 Clamp Base Bottom C...

Page 10: ...even FORWARD to find that perfect illumi nation spot to view your favorite live animal This energy saving JBJ Compact Fluorescent fixture contains a 9 watt 50 50 lamp with a re mote ballast for a cool...

Page 11: ...olved organics and odor 3 Biological Filtration White sponge offers maximum surface area to colonize beneficial bacteria to remove harmful toxins The PICOTOPE starter aquarium offers panoramic viewing...

Page 12: ...ink for 30 seconds or until water runs clear Fill the main body of the PICOTOPE until water reaches the bottom of the clamp for the light fixture Once PICOTOPE is filled plug PICO pow erfilter power c...

Page 13: ...plugged into an electrical socket ADJUSTING THE TELESCOPING ARMS Your PICOTOPE is pre installed with a dual color lamp that offers day light and blue actinic light in one compact design A Plugging th...

Page 14: ...o a minimum A Filter Sponge should be changed on a monthly basis to remove trapped debris and free floating particulate matter A Activated Carbon adsorbs dissolved pollutants and removes the yel low d...

Page 15: ...fts may also occur that may lead to undesirable algae growth 1 Unclamp the light fixture from the tank rim 2 Lay light fixture down on a leveled surface and unscrew light cover 3 Unclip lamp from bulb...

Page 16: ...16 DATE MAINTENANCE...

Page 17: ...17 DATE MAINTENANCE...

Page 18: ...18 DATE MAINTENANCE...

Page 19: ...misapplication or mishandling also voids this war ranty Aquariums must be placed on leveled surfaces or stands designed specifi cally for the Picotope This warranty is limited to the repair or replace...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 Phone 310 672 0480 Fax 310 672 7261 E mail sales jbjlighting com 3730 West Century Blvd Suite 3 Inglewood CA 90303 Transworld Aquatic Ent Inc...

Reviews: