background image

 IDENTIFICATION 

Magnetic Heater 

Case Holder 
Item No: TT-MHC 

Safety Guard 

Item No: TT-SG 

Magnetic Heater 

Case Holder 
Item No: TT-MHC 

Temperature Probe 

Item No: TT-TP 

Magnetic Temp 

Probe Holder 
Item No: TT-MTP 

Summary of Contents for True Temp Titanium

Page 1: ...TRANSWORLD AQUATIC ENTERPRISES INC TITANIUM HEATING SYSTEM Professional Series...

Page 2: ...lug or receptacle getting wet position aquarium stand and tank to one side of a wall mounted recepta cle to prevent water from dripping onto the receptacle or plug A drip loop shown in the Figure at t...

Page 3: ...r or to temperatures below freezing J Make sure an appliance mounted on a tank is securely installed be fore operating it K Read and observe all the important notices on the appliance L This Appliance...

Page 4: ...ake sure hands are completely dry before re plugging into an electrical outlet In order to assure proper electrical connections and polarity replace ment parts and servicing should be performed only b...

Page 5: ...IDENTIFICATION B C A LED TEMPERATURE DISPLAY UP DOWN PUSH BUTTONS HEATING INDICATOR E D Temperature Probe Receptacle 3 PRONG HEATER RECEPTACLE Digital Controller Item No TT 1000 5...

Page 6: ...ICATION F H H G I Magnetic Heater Case Holder Item No TT MHC Safety Guard Item No TT SG Magnetic Heater Case Holder Item No TT MHC Temperature Probe Item No TT TP Magnetic Temp Probe Holder Item No TT...

Page 7: ...single most important factor for a successful aquarium Since fish do not have the ability to regulate their own body tempera ture it is crucial that we provide consistent water temperatures with minim...

Page 8: ...robe grants easy re placement without the need to replace the entire controller in the event it fails The perfect submersible element for fresh or saltwater aquaria Virtually indestructible with the b...

Page 9: ...ion cups that constantly lose their hold Easily place your heater vertically horizontally or at any angle you please with long lasting stability ADVANCED SAFETY CROSS REFERENCE Have you ever noticed t...

Page 10: ...g ele ment where there is a constant flow of water to evenly distribute the heat 4 Connect other half of magnets by placing on the opposite side 1 Insert temperature probe into Magnetic Temp Probe Hol...

Page 11: ...or DOWN buttons ac cordingly Note The TRUETEMP TITANIUM controller has a 1F cycle point Example If controller is set to 77F the heater will turn on at 76F and turn off at 78F This will prevent constan...

Page 12: ...Contact ER2 Controller Malfunction If you require further support or have questions please contact us at Customer Support 877 374 9981 Or email us at support jbjlighting com Or visit our website for a...

Page 13: ...13...

Reviews: