CS100SUB
150W Powered Sub/ Plate Amp
LINE VOLTAGE
Yes/No
Hi/Lo Line
Unit
Notes
US 120vac/60Hz
Yes
108-132
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-264
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
D
n/a
Load Impedance (speaker)
4
Ohms
n/a
Nominal
Rated Output Power
150
Watts
145
1 input driven
THD@ Rated Power
0.08
%
1
22K filter
THD @ 1 Watt
0.1
%
0.5
22K filter
DC Offset
10
mV-DC
20
@ Amplifier Output
Damping factor
>100
N/A
15
50Hz-4 Ohms load
Measured at amplifier PCB speaker out
connector @ 135 Watts into rated
impedance.
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
1 input driven
Line Input (L&R)
19.42
mVrms
±2dB
To 1 Watt
1 input driven
LFE Input
10.2
mVrms
±2dB
To 1 Watt
LFE input driven only
Line Input (L & R) Gain
40.25
dB
±1dB
1 input driven
LFE Input Gain
45.84
dB
±1dB
LFE input driven only
Signal to Noise
SNR-A-Weighted
100
dBA
85
rel. to rated power
A-Weighting filter
SNR-Un-weighted
90
dBr
80
rel. to rated power
22K filter
SNR @ 1W-Un-weighted
60
dBr
60
rel. to 1W Output
22K filter
Residual Noise Floor
1
mVrms
2
Volume @max, using RMS reading
DMM/VOM (or A/P)
Residual Noise Floor
1
mVrms(max)
2
Volume @max, w/ A/P Swept Bandpass
Measurement (Line freq.+ harmonics)
Input Impedance
Line input L&R , LFE
>10
K ohms
n/a
Nominal
Filters
Left & Right Low Pass fixed
Hz
--
±2dB
Order & Q
4th
dB/Octave
n/a
LFE Low Pass fixed
Hz
--
±2dB
Order & Q
2nd
dB/Octave
n/a
Subsonic filter (HPF)
Hz
--
±2dB
Order & Q
2nd
dB/Octave
n/a
Limiter
(yes/no)
YES
--
n/a
Features
LFE Input
YES
Functional
BW limited to 500 Hz, refer to ECR00031
Phase Switch (yes/no)
YES
--
Functional
Volume pot Taper (linear/log
LOG
--
Functional
ATO (Auto-ON)
YES
Functional
Input Configuration
Line In (L,R)
L ,R
--
Functional
RCA inputs: L , R
Line level in LFE
LFE
Functional
Signal Sensing (ATO)
ATO test Frequency
50
Hz
ATO Line Level
2
mV
Functional
2mV@50Hz into Line Input w/ 1 ch.
driven
ATO Turn-on time
5
ms
Functional
Amp connected and AC on, then input
signal applied in excess of 2mV applied
Auto Mute/ Turn-OFF Time
15
minutes
Functional
T before muting, after signal is removed Auto turn off time (T) must be
5min > T <15min
Power on Delay time
3
sec.
Functional
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
10
@ Speaker Outputs
Turn-on Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from ON to OFF
CS100 (CS6100 Subwoofer)
2
Summary of Contents for CS6100
Page 5: ...CS100 CS6100 Subwoofer PACKAGING 4 ...
Page 8: ...CS100 CS6100 Subwoofer EXPLODED VIEW 7 ...
Page 10: ...CS100 CS6100 Subwoofer 9 ...
Page 16: ...CS100 CS6100 Subwoofer 15 ...
Page 17: ...CS100 CS6100 Subwoofer 16 ...
Page 18: ...CS100 CS6100 Subwoofer 17 ...
Page 19: ...CS100 CS6100 Subwoofer 18 ...
Page 20: ...CS100 CS6100 Subwoofer 19 ...
Page 21: ...CS100 CS6100 Subwoofer 20 ...
Page 22: ...CS100 CS6100 Subwoofer 21 ...
Page 23: ...CS100 CS6100 Subwoofer 22 ...