SAFETY PRECAUTIONS
The following check should be performed for the continued
protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water
pipe, conduit, etc.) by connecting a leakage current tester
between the earth ground and all exposed metal parts of the
appliance (input/output terminals, screwheads, metal
overlays, control shaft, etc.). Plug the AC line cord of the
appliance directly into a 120V AC 60Hz outlet and turn the
AC power switch on. Any current measured must not exceed
o.5mA.
ANY MEASUREMENTS NOT WITHIN THE LIMITS
OUTLINED ABOVE ARE INDICATIVE OF A
POTENTIAL SHOCK HAZARD AND MUST BE
CORRECTED BEFORE RETURNING THE APPLIANCE
TO THE CUSTOMER.
Device
under
test
Test all
exposed metal
surfaces
Also test with
plug reversed
(Using AC adapter
plug as required)
AC Leakage Test
Leakage
current
tester
Reading should
not be above
0.5mA
Earth
ground
3-3
Summary of Contents for Party Box 200
Page 41: ...MAIN BOARD PCB LAYOUT TOP...
Page 42: ...MAIN BOARD PCB LAYOUT BOTTOM...
Page 43: ...TOP RGB LAMP BOARD AND KEY BOARD LAYOUT TOP...
Page 44: ...TOP RGB LAMP BOARD AND KEY BOARD LAYOUT BOTTOM...
Page 45: ...BOTTOM RGB LAMP BOARD LAYOUT TOP...