background image

Gateway 900 Installation Manual 

 

Page 4 

 
 
 
 

The Gateways can be ordered with Frame Relay connections using an internal or external 
DSU.  The Gateway 700 provides the same port configuration as the G900 but uses an 
external DSU.   The Gateway 800 provides an integrated 56/64/72 KB DSU.  With the frame 
connection, the Gateways provide a complete router replacement with full protocol 
conversion. 

 
 

Frame Relay Support 

 
The Gateway provides full support for Frame Relay networks, including: 
 

  Supports up to 100 Logical Channels (DLCIs). 
  Both CPE and Access Node configurations. 
  ANSI T1.617 Annex D, Q.933 or LMI Local Signaling. 
  Frame Size to 4096 Bytes. 
  Flow control using individual Committed Information Rate (CIR) for each DLCI. 

 
Our Frame Relay support is certified to ISO and ITU standards by major network 
laboratories.  The X.25 support is certified to European NET2 standards by the ROLAND 
Laboratory. 

© JBM Electronics Co. 

1-800-489-7781 

www.jbmelectronics.com

 

 

Summary of Contents for 900

Page 1: ...Gateway 900 Installation Manual...

Page 2: ...ibed in this manual are subject to change without notice Revision Level 5 0 Revision Date 1 3 2004 Copyright 2004 by JBM Electronics Co For further information contact JBM Electronics Co 4645 LaGuardi...

Page 3: ...network Allows TCP IP devices to access a Legacy protocol network Provides host and terminal emulation for all polled protocols which allows up to 100 physical devices to be connected to one serial po...

Page 4: ...to an IP network The Gateway can help protect the investment in Legacy devices when moving to a new network The Gateway s security software can be used to protect attached devices from unauthorized a...

Page 5: ...the Gateway All of the protocol specific diagnostics such as LUSTATS Notify and Status and Sense Bytes are supported Extensions to the Telnet or SNMP commands are available as a special order Network...

Page 6: ...ocol conversion Frame Relay Support The Gateway provides full support for Frame Relay networks including Supports up to 100 Logical Channels DLCIs Both CPE and Access Node configurations ANSI T1 617 A...

Page 7: ...p to 56 KB The serial interface is RS 232C DCE with DTE Enabled through a cable adapter G50 adapter DB 25 Port 2 WAN Port supports Frame Relay or X 25 at speeds up to T1 E1 through the integrated DSU...

Page 8: ...Adapter must be used The RS 232C cable and adapter are listed in the Cables Manual on the CD supplied with the unit 6 Connect the phone cable to the WAN Port Port 2 7 Plug the Gateway into a power out...

Page 9: ...structions JBM Administrative Menu and other features Follow these instructions to access the Gateway through the Console Port 1 Verify your system is connected to the COM Port on the Gateway This can...

Page 10: ...ve and must be entered in the appropriate case This userid and password is used for Console and Telnet access Note We recommend you change password using the instructions in the Gateway Operations Man...

Page 11: ...ace definitions for the WAN connection The program usr sbin wancfg should be used to create the configuration file s It is a GUI ncurses based configurator that contains all wanpipe options as well as...

Page 12: ...select wanpipe1 and hit the SELECT button 4 Choose WAN Protocol Definition and choose Frame Relay 5 Select Hardware Setup Select Adapter Type When selecting the Adapter Type note the PORT option Usual...

Page 13: ...ame e g iptables o wp1_fr16 will give you an error Operation Mode WANPIPE is for IP Routing API is used for custom API applications DLCI Protocol Setup In this section leave everything as default Unle...

Page 14: ...cators The Gateways have LED indicators that can be used to isolate problems The LEDs indicate the following activity LED COLOR FUNCTION NORMAL STATUS Power Yellow Signifies that power is available to...

Page 15: ...Up to 115 200 bps Interface One Male DE 9 RS 232C DTE mode DCE mode with adapter cable Management Console Port CLI Access through async connection IP Protocol SNMP and Telnet LED Indicators Serial Por...

Page 16: ...according to IEC 60 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions France and Peru only This unit cannot be powered from IT supplies...

Page 17: ...on acc s doit tre facile Vous ne pouvez mettre l appareil hors circuit qu en d branchant son cordon lectrique au niveau de cette prise L appaireil fonctionne une tension extr mement basse de s cirot q...

Page 18: ...000 3 2 IEC 61000 3 3 EN 61000 3 3 ETSI EN 300 386 V1 2 1 1998 11 CE Statement Europe This product complies with the European EMC Directive 89 336 EEC Regulatory Notices FCC Statement This equipment h...

Page 19: ...DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment must be used only with cables with comply with IEEE 802 3 CSA Statement This Class A digital apparatus meets all...

Page 20: ...be reverse engineered or used for any other purpose other than in and with the computer hardware sold by JBM Electronics Extended Warranty Program JBM offers an extended warranty for the Gateway This...

Reviews: