Gateway 900 Installation Manual
Page 5
Installation
The manuals used with the Gateways are:
Manual
Usage
Installation Unpacking
and
installing the Gateway
Setup
Defining the Gateway’s configuration
Operations Controlling
the
Gateway
Cables
Cable Wire Lists
The Setup and Operations Manuals are on the CD supplied with the Gateway.
1.
Remove the JBM Electronics Gateway 900 from the shipping carton.
2.
Inspect the Gateway for shipping damage. If any damage is found, retain the
carton and contact the carrier.
3.
Connect the cables according to the following table:
Port
Description
Connector
Port 0 Ethernet Port - supports IP protocols on a 10/100BaseT
port.
RJ-45
Port 1 Serial Port - supports Legacy protocols at speeds up to 56
KB. The serial interface is RS-232C DCE with DTE
Enabled through a cable adapter (G50-adapter).
DB-25
Port 2 WAN Port - supports Frame Relay or X.25 at speeds up to
T1/E1 through the integrated DSU.
RJ-45
Port 5 Console Port (on back) – supports async at 115.2 KB. The
serial interface is RS-232C DTE with DCE selectable
through a cable adapter.
DE-9
4.
Connect the Ethernet cable to the Ethernet port (Port 0). Verify the cable is
connected to a network.
WARNING:
RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot be used as
standard traditional telephone sockets, or to connect the unit to a traditional PBX or public
telephone network. Only connect RJ-45 data connectors, network telephony systems, or
network telephones to these sockets. Either shielded or unshielded data cables with shielded
or unshielded jacks can be connected to these data sockets.
© JBM Electronics Co.
1-800-489-7781