background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/25

LED PIPE CONTROLLER

HOW TO USE:

MENU STRUCTURE:

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/25

LED PIPE CONTROLLER

INSTALLATION STEPS:

To be sure that the LED PIPE system works properly you must follow the steps below every time
you change the number of tubes, put tubes at different locations or simply disconnect and
reconnect one or more tubes:

INSTALL ALL TUBES:

Refer to the installation manual included with each LED PIPE RGB 230V for

proper installation.

INSTALL THE CONTROLLER:

o

Put the controller in a suitable place.

o

Connect the supplied DC adapter to the controller.

o

Connect the signal output to the signal input of first LED PIPE.

TEST CONNECTIONS:

we will test the connection between the controller and the LED PIPES.

o

Connect the mains to the first LED PIPE. All the LED PIPES will start working in automatic
mode.

o

Switch the controller on

o

Press the MENU button until the display shows “ReSet Mode”.

o

Press the ENTER button: display shows “ReSet?”. Use the UP/DOWN buttons to change
the blinking “NO” to “YES” and press ENTER to confirm.

o

When the display shows “ReSetting OK!”, all the connected LED PIPES should turn white.
This indicates that the controller is well connected.

SET THE NUMBER OF LED PIPES MANUALLY:

To be able to produce nice programs, the

controller needs to know how many LED PIPES are connected.

o

Use the MENU button to select “1. SystemSet” and press the ENTER button.

o

The display shows “1.1 Tube Amount”

press ENTER, the current amount starts blinking.

o

Use the up and down buttons to set the exact number of connected tubes.

o

Press the ENTER button to confirm

o

Press the MENU button twice to go back in the main menu.

Remark:

If the number of connected tubes doesn’t match the number set on the controller, the

system will not work properly. Some tubes will even not work at all!

DMX512 ADDRESSING:

o

Use the MENU button to select “1. SystemSet” and press the ENTER button.

o

Press the UP and DOWN buttons to select “1.2 DMX512 Addr” and press ENTER.

o

The current DMX-address starts blinking.

o

Use the UP and DOWN buttons to set the new DMX-address and press ENTER to confirm.

o

Press the MENU button twice to go back in the main menu.

STANDALONE MODE:

This is the simplest way to operate the LED PIPE system.
Use the MENU, ENTER and UP/DOWN buttons to select the desired mode or patterns from the list that
you see in the MENUSTRUCTURE. There are 4 modes, each with 8 different patterns:

o

Auto mode:

8 automatic patterns (speed to be selected, not music controlled)

o

When a pattern is selected you still have to select the desired speed (speed is blinking).
Confirm your choice by pressing ENTER.

o

For some patterns you also have to choose in which direction the pattern should run

(current direction is flashing) choose “left” or “right” and confirm with ENTER.

o

Sound mode:

8 music activated patterns

o

For some patterns you have to choose in which direction the pattern should run

(current direction is flashing) choose “left” or “right” and confirm with ENTER.

o

dB mode:

8 music activated “VU meter-like” patterns

o

When a pattern is selected you still have to select the desired speed (speed is blinking).
Confirm your choice by pressing ENTER.

o

You also have to choose in which direction the pattern should run

(current direction

is flashing) choose “left” or “right” and confirm with ENTER.

o

Hold mode:

8 built-in full color patterns

o

Just choose the desired color and confirm with ENTER.

Summary of Contents for LED PIPE

Page 1: ...C cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited LED PIPE Controller Operation Manual Mode d emploi Gebruiksaanwijzing Bedienung...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...ug the unit when it is not used for a longer time or before you start servicing The electrical installation should be carried out by qualified personal only according to the regulations for electrical...

Page 4: ...confirm o Press the MENU button twice to go back in the main menu Remark If the number of connected tubes doesn t match the number set on the controller the system will not work properly Some tubes w...

Page 5: ...Canal1 choix du mode de fonctionnement o Canal2 choix du motif lumineux en fonction du mode de fonctionnement s lectionn o Canal3 vitesse direction Beau bo tier en m tal Fonction de sauvegarde automat...

Page 6: ...ctionnement s rieux arr tez toute utilisation de l appareil et contactez votre revendeur imm diatement Utilisez l emballage d origine si l appareil doit tre transport Pour des raisons de s curit il es...

Page 7: ...ur ENTER o L adresse DMX en m moire commence clignoter o Utilisez les touches UP et DOWN pour encoder la nouvelle adresse DMX et appuyez sur ENTER pour confirmer o Appuyez deux fois sur la touche MENU...

Page 8: ...raat uit de buurt van kinderen Dit apparaat mag niet door onervaren personen bediend worden De maximum veilige omgevingstemperatuur is 40 C Gebruik het apparaat dus niet bij hogere temperaturen Trek a...

Page 9: ...amma s te kunnen produceren moet de controller weten hoeveel LED PIPES er aangesloten zijn o Gebruik de MENU toets om 1 SystemSet te selecteren en druk daarna op de ENTER toets o De display toont 1 1...

Page 10: ...re Geschwindigkeit und Intervall Zeiten f r die Muster Automatischer Sicherungsmodus d h der letzte Modus aller TUBELEDs wird gespeichert VOR DEM GEBRAUCH Inhalt berpr fen berpr fen Sie den Karton auf...

Page 11: ...n BESCHREIBUNG FRONTANSICHT 1 LCD Display Zeigt alle wichtigen Informationen ber den Arbeitsmodus und Parameter des Ger tes an 2 MENU TASTE um zwischen den Hauptbetriebsmodi hin und her zu wechseln Sy...

Page 12: ...MX Adresse einzustellen und dr cken Sie ENTERzur Best tigung o Dr cken Sie den MENU Knopf zweimal um wieder ins Hauptmen zu gelangen STAND ALONE MODUS Das ist der einfachste Weg um die LED PIPE zu bed...

Page 13: ...m xima temperatura ambiente para un funcionamiento seguro es de 40 C No utilice la unidad a temperaturas ambiente superiores Desenchufe siempre la unidad cuando no vaya a ser utilizada durante un lar...

Page 14: ...ntidad actual empieza a parpadear o Utilice los botones UP DOWN para establecer el n mero exacto e tubos conectados o Pulse el bot n ENTER para confirmar o Pulse el bot n MENU dos veces para volver al...

Page 15: ...sistema por medio de DMX ESPECIFICACIONES Entrada de red Adaptador CC 230V 50Hz 12Vcc 800mA Patronespreprogramados 32 M x n mero de tubos hasta1000 unidades Conexiones DMX 3 clavijas XLR macho hembra...