background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/36

PHAETON

DESCRIPTION:

1. Internal microphone
2. Microphone sensitivity
3. ¼” Jack input for the optional CA-8 hand

controller

4. DMX input
5. DMX output
6. Cooling fan
7. Mains

input

with

IEC

socket

and

integrated fuse holder, connect the
supplied mains cable here.

8. Hanging bracket with 2 knobs on both

sides to fasten the unit and a mounting
hole to fix a mounting hook.

9. DIP switches, used to set the DMX-

starting address of the unit.

10. 60 optical lenses on the front part of the

unit.

11. Lamp compartment

LAMP (RE)PLACEMENT

In case of replacement of the lamp or maintenance, do not open the fixture within 15
minutes until the unit cools down after switching off. Always unplug the unit before
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When replacing
parts, please only genuine spare parts.

Switch off the unit and unplug the mains cable.

Wait for about 15 minutes until the unit has been cooled down.

Use a screwdriver to unscrew the 2 screws that close the lamp
compartment of the fixture (see “A” on the picture).

On the inside you will see the lamp socket. Tear the lamp socket
gently out of the lamp compartment.

Unplug the old lamp. Hold the lamp socket while unplugging the
lamp instead of pulling the cable!

Hold the lamp socket while pressing the new lamp gently in the
socket.

Attention!

This unit uses a special circular lamp! Check the label

on the backside of the device or see the technical specifications in
this manual to know which lamp should be used. Never install
lamps with a higher wattage! Lamps with higher wattage generate
temperatures the device was not designed for. If the device uses a
lamp transformer, it will burn due to current overload.

Don’t touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you touched the
lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off before installing.

Put the new lamp back inside the unit. Be sure that the wires don’t touch the lamp.

Close the lamp compartment with the 2 screws.

Done!

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/36

PHAETON

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

OPERATING INSTRUCTIONS

Once connected to the mains the device starts running.

Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.

Do not switch the unit on and off in short time intervals as this reduces the lamp life.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare-hands during its
operation.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons

suffering from epilepsy.

1. Standalone 1unit:

Just connect the unit to the mains and put on some music. The unit will start working automatically to the
rhythm of the music.

2. Two or more units in master/slave setup:

Connect 2 or more units together using good quality balanced XLR microphone cables. The unit that has no
cable connected to its input will react as master, the others are the slave units.

Important: On the master unit the DMX address MUST be set to 001.

(first DIP switch =

ON, all other are OFF)

The slave units can have any DMX address value but NOT 001!

You can inverse the behavior of one or more slave units by changing the position of DIP-switch
n°10 on these slaves. Just try it and see if the effect becomes better. Changing DIP-switch n°10
on the master has no effect.

3. Connect the optional CA-8 controller for more control:

The CA-8 controller can only be used in standalone or master/slave mode. Connect the
controller to the jack input of the first unit (master). Now you can control all the connected units:

Stand by

Blackout the unit

Function

1. Strobe in sync
2. Strobe in 2-light show

1.Slow/middle/fast speed clockwise rotation
2.Slow/middle/fast speed counterclockwise
rotation

Mode

Sound (LED OFF)

Slow ~ no sound (LED ON)

4. Controlled by universal DMX-controller:

The DMX-protocol is a widely used
high speed signal to control intelligent
light equipment. You need to “daisy
chain” your DMX controller and all the
connected units with a good quality
balanced cable.
To prevent strange behavior of the light effects, due to interferences, you must use a
90

Ω

to 120

Ω

terminator at the end of the chain. Never use Y-splitter cables, this simply

won’t work!
Make sure that all units are connected to the mains.

Summary of Contents for Phaeton

Page 1: ...Reproduction or publication of the content in any manner without express permission of the publisher is prohibited PHAETON Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...cking material as much as possible CAUTION ENGLISH OPERATION MANUAL JB SYSTEMS 2 36 PHAETON A new light effect sometimes causes some unwanted smoke and or smell This is normal and disappears after som...

Page 4: ...ad of 10times the device s weight Always use a certified safety cable that can hold 12times the weight of the device when installing the unit This secondary safety attachment should be installed in a...

Page 5: ...be totally free from any deformation When an optical lens is visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced...

Page 6: ...que possible Un effet lumi re neuf peut provoquer de la fum e et ou une odeur non souhait e qui devrait dispara tre apr s quelquesminutes Afin d viter tout risque d incendie ou de d charge lectrique...

Page 7: ...pas de personnes non concern es lors de l installation la d sinstallation ou la maintenance Placez l appareil dans un endroit bien ventil loign de tout mat riau ou liquide inflammable L appareil doit...

Page 8: ...cern es lors de la maintenance Mettez l appareil hors tension d branchez le cordon d alimentation et attendez que l appareil ait refroidi Pendant l inspection les points suivants doivent tre v rifi s...

Page 9: ...betekent Lees de handleiding Dit symbool bepaalt de minimumafstand van te belichten voorwerpen De minimumafstand tussen projector en het verlichte voorwerp moet meer dan 1 meter zijn Om het milieu te...

Page 10: ...ngen vergt veel ervaring U behoort de grenzen te respecteren aan de werklast erkende installeringmaterialen moeten worden gebruikt de veiligheid van het ge nstalleerde toestel moet regelmatig worden g...

Page 11: ...stallatieplaats vrij is van ongewenste personen tijdens het onderhoud Zet het toestel uit trek de netstekker uit het stopcontact en wacht tot het toestel is afgekoeld Bij inspectie moeten de volgende...

Page 12: ...esen CAUTION DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 20 36 PHAETON Dieses Symbol stellt fest der minimale Abstand von beleuchteten Gegenst nden Der minimale Abstand zwischen Projektor und dem belichtet...

Page 13: ...edrigen Durchg ngen oder in der N he von Sitzgelegenheiten installieren Vor Montage sicherstellen dass die gew hlte Position wenigstens das 10 fache Ger tegewicht aufnehmen kann Zur Aufh ngung stets g...

Page 14: ...schalten Netzstecker ziehen und warten bis es sich abgek hlt hat W hrend der Wartung sind folgende Punkte ganz besonders zu beachten S mtliche Schrauben zur Installation und Befestigung jeglicher Teil...

Page 15: ...o Para proteger el medio ambiente recicle el material de embalaje en la medida de lo posible Un nuevo efecto luminoso provoca a veces humo y u olor no deseados Esto es normal y desaparece despu s de a...

Page 16: ...que el aparato en un lugar bien ventilado lejos de materiales y o l quidos inflamables El aparato debe colocarse a al menos 50 cm de las paredes El dispositivo debe instalarse lejos del alcance de las...

Page 17: ...ON MANTENIMIENTO Aseg rese de que debajo de la zona del lugar de instalaci n no haya personas durante el mantenimiento Apague la unidad desenchufe el cable de red y espere hasta que la unidad se haya...

Page 18: ...mal e tempor ria De modo a evitar risco de fogo ou choque el ctrico n o exponha este produto a chuva ou humidade De forma a evitar a forma o de condensa o no interior da unidade ao transport la para a...

Page 19: ...rcundantes A unidade deve ser instalada fora do alcance das pessoas afastada de reas onde as pessoas possam passar ou sentar se Antes de proceder instala o certifique se que a rea seleccionada pode su...

Page 20: ...de alimenta o da corrente e aguarde que a unidade arrefe a Durante a inspec o dever verificar os seguintes pontos Todos os parafusos utilizados nas pe as da unidade e na instala o dever o estar aperta...