background image

 

 

Monocular Microscope 

 

Bimc-01NS

 

Ver.1.0.1

 

®

 

 

I N T E R N A T I O N A L

 

OPERATION MANUAL

  

JC LAB Microscope - JAPAN

 

www.jc-lab.jp      -      info@jc-lab.jp

 

Summary of Contents for Bimc-01NS

Page 1: ...Monocular Microscope Bimc 01NS Ver 1 0 1 I N T E R N A T I O N A L OPERATION MANUAL JC LAB Microscope JAPAN www jc lab jp info jc lab jp ...

Page 2: ...icroscope at a Glance Page 4 3 0 Introduction Page 5 4 0 Unpacking and Assembly Page 5 5 0 Microscope Accessories Page 6 7 6 0 Using the Microscope Page 8 7 0 Maintenance Page 9 8 0 Electrics Page 10 9 0 Recycling and Revcovery Page 10 ...

Page 3: ...ages incurred directly or indirectly from error omissions or discrepancies between the wifi microscope and the manual Trademarks JC CAM logo are registered trademarks of JC LAB Corporation Wi Fi is registered trademark of Wi Fi Alliance USB the USB logo and USB interface are trademarks or registered trademarks of USB Licensing LLC Other trademarks are registered trademarks not listed above may be ...

Page 4: ...ed by wire device like for example mobile phones Because Wireless products operate within the guidelines found in radio frequency safety standards and recommendations JC LAB believes Wireless products is safe for use by consumers These standards and recommendations reflect the consensus of scientific community and result from deliberations of panels and committees of scientists who continually rev...

Page 5: ...r if you are having problems operating devices you may need to contact JC LAB for additional technical assistance Before you call Some problem you experience may be related to software apps or the operating system so it is importance that you investigate other sources of assistance first Before contacting JC LAB try the following Review troubleshooting sections in the documentation supplied withyo...

Page 6: ...Head 2 Stand 3 Nosepiece 4 Objective Lens 5 Attachable Mechanical Stage 6 Stage 7 Condenser Knob 8 Fine Adjustment Knob 9 Coarse Adjustment Knob 10 Light Intensity Adjust 11 Power Plug DC 5V 12 On Off Switch 13 Viewing Head adjust 14 Iris Turning 15 Y axis movement 16 X axis movement 17 Light Source Cover 1 Microscope at a Glance 2 9 5 6 8 15 16 13 3 4 11 7 14 17 10 2 0 Microscope at a Glance BIMC...

Page 7: ...ontainer Remove the tape from the edge of the container and lift the top half of the container Take some care to avoid that the optical items objectives and eyepieces fall out and get damaged Lift the microscope from the container and put it on a stable desk 4 2 The objectives are assembled on the microscope If removed the objectives from the microscope then insert them into the microscope nosepie...

Page 8: ... Auto and Manual adjustment White Balance Real time auto and manual RB adjustment Preview resolution USB HDMI 5G Wi Fi 30FPS 4000x3000 3840x2160 2592x1944 1920x1080 Spectral Characteristics 380 650nm Record Format Snapshot Format JPG BMP PNG TIFF Resolution 4000x3000 3840x2160 2592x1944 1920x1080 Record Format AVI MP4 file Resolution 30fps 1920x1080 AVI 1920x1080 1600x1200 MP4 Supporting protocol ...

Page 9: ... NIST certification Lens Cleaning Tissue for slide cleaning 5 0 Microscope Accessories BIMC S09A TOO 155E MiniPC for JC Cam series Wifi eyepiece to screen on the TV BIMC MIPC06 Digital Drying Cabinet Cap 60L CHD 60 Slide Folder hold 20pcs of slide MCS SL01A ...

Page 10: ...into the power socket on the back of the microscope to charge it and turn the switch to the charge mode on the right side of the main body 6 4 Rotate the coarse focusing knob to bring the slide into focus with the 4X objective Adjust the fine focusing knob to get the image sharp and clear 6 5 Adjust the aperture of the iris diaphragm to set the numerical aperture of the illuminator thus controllin...

Page 11: ...he surface of any optical items with your hands Fingerprints can damage the optics Use solvents neither on the microscope nor on the optics Disassemble objective or eyepieces to attempt to clean them Mishandle or impose unnecessary force on the microscope Clean the unit with volatile solvents or abrasive cleaners Attempt to service the microscope yourself 7 3 How to change the lamp Before changing...

Page 12: ...fe should be collected separately from other waste The separate collection of this equipment at the end of its lifetime is organized and managed by the producer The user will have to contact the manufacturer and follow the rules that he adopted for end of life equipment collection The collection of the equipment for recycling treatment and environmentally compatible disposal helps to prevent possi...

Reviews: