This microscope is a scientific precision instrument designed to last for many 
years with a minimum of maintenance. It is built to high optical and 
mechanical standards and to withstand daily classroom and laboratory use.  

JC LAB reminds you that this manual contains important information on safety 
and maintenance, and that it must therefore be made accessible to the 
instrument users. JC LAB declines any responsibility deriving from instrument 
use that does not comply with this manual.

 

Page 5

 

4.1 

The  microscope  is  housed  in  a  moulded  Styrofoam  container.  Remove  

the  tape  from  the edge of the container and lift the top half of the container. 
Take some care to avoid that the optical items (Glass Stage Plate and 
eyepieces) fall out and get damaged. Lift the microscope from the container 
and put it on a stable desk. 

Do not touch with bare hands optical surfaces such as lenses, filters or 
glasses. Traces of grease or other residuals may deteriorate the final 
image quality and corrode the optics surface in a short time.  

4.3 Assembling the microscope  

1. 

When handling the components, especially the optical parts, avoid touching any lens surfaces 

with bare hands or fingers as fingerprints and grease stains affect image quality.

 

2. 

After unpacking the stand, put it on a stable and flat table. Loosen the locking screw of the 

head holder, adjust the height of the head holder and lock the locking screw again.  

Make sure that the support collar is secured firmly below the head holder along the vertical post. 

This is important as this collar keeps the microscope from sliding down the column.

 

3. 

The head holder should rest on the support collar and both the head holder locking screw and 

the collar locking screw should be tightened.

 

4. 

Put the stereo body onto the head holder and lock it using the locking screw located on the 

right hand side of the head holder. To maintain the best stability, you are advised to lock the 

screw on the left hand side of the head holder as well. 

5. 

After removing the wrapping papers and packing materials around the eyepieces and other 

optical parts (avoid touching the lens surfaces), carefully place the eyepieces into the eyepiece 

tubes.  

6.Before turning on the power, plug the illumination power cord into the socket at the top of the 

column. Next, plug the power cord of the main frame into the local power supply. 

 

3.0 Introduction

 

4.0 Unpacking and Assembly

 

Summary of Contents for Bimc-04ns05

Page 1: ...GUIDA UTENTE MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS BEDIENUNGSANLEITUNG Ver 2 1 6 I N T E R N A T I O N A L JC LAB Microscope JAPAN www jc lab jp info jc lab jp Solo versione PDF Nur PDF Versi...

Page 2: ...Page 4 3 0 Introduction Page 5 4 0 Unpacking and Assembly Page 5 5 0 Microscope Accessories Page 6 7 6 0 Using the Microscope Page 8 9 7 0 Maintenance Page 10 8 0 Troubleshooting Page 11 9 0 Electrics...

Page 3: ...ges incurred directly or indirectly from error omissions or discrepancies between the wifi microscope and the manual Trademarks JC CAM logo are registered trademarks of JC LAB Corporation Wi Fi is reg...

Page 4: ...d by wire device like for example mobile phones Because Wireless products operate within the guidelines found in radio frequency safety standards and recommendations JC LAB believes Wireless products...

Page 5: ...if you are having problems operating devices you may need to contact JC LAB for additional technical assistance Before you call Some problem you experience may be related to software apps or the oper...

Page 6: ...our local distributor to ensure the features 1 Zoom Adjustment Knob 2 Focus Adjustment Knob 3 Reflected LED 4 Transmitted Reflected LED light intensity switch 5 Standard Base 6 Power Cable 7 Stage Pla...

Page 7: ...y the optical parts avoid touching any lens surfaces with bare hands or fingers as fingerprints and grease stains affect image quality 2 After unpacking the stand put it on a stable and flat table Loo...

Page 8: ...nsor Optical Format 1 2 5 5 90mm x 4 5mm H x V Diagonal 7 0mm Pixel Size 2 2 m x 2 2 m Dynamic Range 74 3dB SNRmax 40dB Exposure 3 9ms 320ms Automatic and Manual White Balance Real time auto single au...

Page 9: ...NIST certification Lens Cleaning Tissue for slide cleaning 5 0 Microscope Accessories BIMC S09A TOO 155E MiniPC for JC Cam series Wifi eyepiece to screen on the TV BIMC MIPC06 Digital Drying Cabinet C...

Page 10: ...he microscope is adjusted to this user Other users will have different IP s and different focusing abilities 6 3 Operation Once the microscope has been setup in its working location with all of the co...

Page 11: ...ion Adjust the right eyepiece diopter until the image seen through the right eyepiece is clear and sharp 5 Repeat the procedure for the left eyepiece Next check the image focus for the entire zoom ran...

Page 12: ...ying voltage of your region matches with the operation voltage of the equipment and that the lamp switch is in off position Users should observe all safety regulations of the region The equipment has...

Page 13: ...is not good Contrast is poor Details are indistinct Image glares Dust or dirt on lenses objectives eyepieces Clean thoroughly Focus is not even Slide holder is not flat Move the specimen to a flat po...

Page 14: ...nd of its useful life should be collected separately from other waste The separate collection of this equipment at the end of its lifetime is organized and managed by the producer The user will have t...

Reviews: