Maintenance
Prior to any adjustment, maintenance or ser-
vice work disconnect the mains power plug!
WARNING!
General maintenance measures
•
Wipe chips and dust off the machine from
time to time using a cloth. In order to
extend the service life of the tool, oil the
rotary parts once monthly. Do not oil the
motor.
•
When cleaning the plastic do not use
corrosive products.
Brush inspection
Check the carbon brushes after the first 50
operating hours with a new machine, or when
new brushes have been fitted. After carrying
out the first check, repeat the check every 10
operating hours.
If the carbon is worn to a length of 6 mm,
or if the spring or contact wire are burned
or damaged, it is necessary to replace both
brushes. If the brushes are found to be usable
following removal, it is possible to reinstall
them.
Service information
Please note that the following parts of this
product are subject to normal or natural wear
and that the following parts are therefore also
required for use as consumables.
Wear parts*: Carbon brush, saw blade, table
inserts, dust bags, batteries,
* Not necessarily included in the scope of
delivery!
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer‘s mains connection as well as the
extension cable used must also comply with
these regulations.
•
The product meets the requirements of
62841-3-9 and is subject to special
connection conditions. This means that
use of the product at any freely selectable
connection point is not allowed.
•
Given unfavorable conditions in the power
supply the product can cause the voltage to
fluctuate temporarily.
•
The product is exclusively intended for use
at connection points that have a continuous
current-carrying capacity of at least 100 A
per phase.
•
As the user, you are required to ensure,
in consultation with your electric power
company if necessary, that the connection
point at which you wish to operate the
product meets the specified requirements.
Kinks where the connection cable has been
improperly fastened or routed.
Important information
In the event of an overloading the motor will
switch itself off. After a cool-down period (time
varies) the motor can be switched back on
again.
Maintenace and electrical connection