P/N 960-000175R_Rev. A {EDP #233426}
© 2014, JAPAN CASH MACHINE CO., LTD.
3 3
Series Banknote Validator (DBV-400) Integration Guide
LED F
LASH
R
EJECT
C
ODE
C
ONDITIONS
Table 23 lists the various LED Flash Reject Code causes & solutions for Banknotes
Table 23
LED Flash Reject Codes
Normal
Operation
Performance
Test
Error
Causes and Solutions
LED
Sequence
LED
Sequence
Yellow
(3)
Yellow
(2)
Magnification
Abnormal
When adjusting Banknote data, Sensors detected an abnormal Banknote
magnification condition.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(3)
Denomination
Error
The Validation Sensor detected an abnormal Banknote Type.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(4)
Pattern Error
The Validation Sensor detected an abnormal Banknote Type.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(5)
Photo Level Error
While transporting a Banknote, transparent tape was detected.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(6)
Banknote Length
Abnormal
The Validation Sensors calculated a Banknote length longer or shorter than
the specified value.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(7)
2-Color Margin
Abnormal
The Validation Sensors calculated that the 2-Color Banknote margin was
greater than the specified value.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Yellow
(8)
Counterfeiting
Banknote Action
The Banknote has been validated as a Counterfeit Banknote.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
Yellow
(3)
Yellow
(9)
3-Color
Comparison
Abnormal
The Validation Sensors calculated a 3-Color comparison that was greater
than the specified value.
[Solution] Check that the Banknote is not damaged nor exhibiting unfit
conditions. Refer to “Banknote Fitness Requirements” on page 4 for
unacceptable Banknote types.
[Relative Parts] Validation Sensor.
If the error is not resolved, change the above related part or parts.
Yellow
(3)
Green
(1)
Skewed Insertion
Error
The Banknote has been inserted in an incorrect/crooked direction.
[Solution] Insert a Banknote in the proper direction.
If the error is not resolved, insert a different Banknote.
Yellow
(3)
Green
(2)
Remaining
Banknotes
Returned
While Initializing, a Banknote remaining in the DBV-400 Unit’s Validation
path has been returned.
Yellow
(3)
Green
(3)
Banknote
Transportation
Abnormal
Sensors detected Banknotes remain in the validation path, or none existed
during an abnormal timing interval.
[Solution] Check that the following parts are properly assembled and/or
Harness connected. Clean or adjust the following parts and Sensors.
[Relative Parts] Entrance Sensor, Centering Guide Sensor, Validation
Sensor, PB Entrance Sensor, PB Exit Sensor, Exit Sensor.
If the error is not resolved, change the above related part or parts.