P/N 960-100929R_Rev. 3 {EDP #148849}
© 2012, Japan CashMachine Co., Limited
1 - 7
General Information
iVIZION® Series Next-Generation Banknote Acceptor Unit
Section 1
Specification (iVIZION LD Version)
T
ECHNICAL
S
PECIFICATIONS
E
NVIRONMENTAL
S
PECIFICATIONS
Table 1-8
iVIZION LD Version Technical Specification
Acceptance Rate
*
:
*. Refer to the specific Country’s “Software Information Sheet” for each Country’s particular Banknote acceptance rate.
98% or greater
Note: The following Banknote types are excluded:
a) Banknotes with unclear graphics
b) Double (dual) notes
c) Worn, dirty, wet, stained, torn or excessively wrinkled Banknotes
d) Banknotes having folded corners or edges
e) Banknotes having the wrong cut dimensions or a printing displacement
f) Returned Banknotes because of incorrect or failed insertion.
Banknote Types Accepted:
Long edge: 110-170 mm (4.33-6.69 in.)
Short edge: 60-85 mm (2.36-3.35 in.).
Barcode Coupon
†
:
†. Refer to the specific Country’s “Bar Code Coupon Specification” for more details.
Standard Specification
a) Read Code interleaved: 2 of 5
b) Narrow Bar: 0.5mm-0.6mm (0.019-0.023 in.)
c) Wide Bar: Narrow Bar = 3:1
d) Characters: 18 Characters
e) Print Position: Middle (by dividing a Coupon equally on the left, right, top and
bottom of the Coupon’s exact center)
f) Print Width: Wider than 10mm (0.39 in.).
Insertion Direction:
Refer to the specific Country’s Software Information Sheet.
Processing Speed:
Approximately 2 seconds from Banknote insertion to Vend signal output.
Validation Method:
Optical
Diagnostic Indicators:
Power LED, Status LED, Bezel LED (Optional)
Escrow:
1 Note
Fraud Detection:
Equipped
Interface
‡
:
‡. The Interface Harness connecting to the Host should be less than 3m.
USB Interface: USB Specification Rev.2.0
Serial Interface: Photo-Coupler Isolation
Serial Interface: RS232C Communication Protocol.
Table 1-9
iVIZION LD Version Environmental Specification
Operating Temperature:
5º C to +50º C (41º F to 122º F)
Storage Temperature:
-20º C to +70º C (-4º F to 158º F)
Relative Operating Humidity:
15% to 85% RH (non-condensed)
Relative Storage Humidity:
15% to 85% RH (non-condensed)
Installation:
Indoors Only
Hydrothermal Condition Table
[°C]
[RH%]
Allowable Operating
Temperature and
Humidity Range
35°C/85%
50°C/40%