P/N 960-100929R_Rev. 3 {EDP #148849}
© 2012, Japan CashMachine Co., Limited
2 - 9
Installation
iVIZION® Series Next-Generation Banknote Acceptor Unit
Section 2
Cleaning Procedure
To clean the lenses, use a lint-free, Micro-Fiber
Cloth and a mild non-abrasive detergent such as
liquid dish soap mixed with water to wipe the dirt
from the Lenses. It is important to keep the
Banknote Path, Rollers, and Belts clean. Use a soft-
lint free, Micro-Fiber Cloth or a Cotton Swab to
wipe dirt and stains from the surfaces of the Optical
Sensors, Rollers and Belts. The Sensor Lenses are
transparent, and made of a polymer material; Han-
dle them with care. When the Unit is exposed to
liquid such as water, wipe and thermally dehydrate
dry the wet areas immediately. Repeat the cleaning
process as needed until the Transport Path is free of
contaminants.
Sensor Cleaning Procedure
1. Turn
the
iVIZION
®
Unit Power OFF.
2. Clean the Sensors and lenses in the Acceptor
Unit, the Transport Unit and on the Cash Box
itself. If necessary, remove each Unit and/or open
their Upper Guides for cleaning. See Figure 2-10
and Table 2-12 to locate all cleaning locations.
iVIZION Optional LD Version Unit
Installation
Mounting holes are provided in the LD Frame Unit
to attach the iVIZION
®
LD Unit to a related
Machine during installation. Perform the following
steps to install the iVIZION
®
LD Version Unit into
the related Machine’s Frame configuration:
1. Install the Interface Harness to the Frame
Grounding Plate (FG PLT) (See Figure 2-8
a
)
using the two (2) Floating Collars (See Figure 2-8
b
1
&
b
2
), the related single (1) M2.6x12 W
Washer Screws (See Figure 2-8
c
&
d
), and the
single (1) M2.6 Nylon Nut (See Figure 2-8
e
)
onto the upper Frame Assembly Bracket. See the
Figure 2-8 circled inset to visually see the com-
pleted assembly as required.
2. Bolt the bottom side of the
iVIZION
®
LD Frame
into its intended Machine’s
location using four (4)
M3x6 Screws on both bottom sides of the Frame
(2 Screws on each side as shown in Figure 2-9).
Figure 2-7
Retrieving Cash Box Banknote Jam
Pull Out
a
c
b
Caution: Do not allow any fluid to remain
on internal components, especially on
the Anti-Strings Mechanism and in the
Feed-in Sensor’s grooved areas.
Caution: Do not use Alcohol, thinner or
citrus based products for cleaning any
Banknote transport Sensors or surfaces.
The lenses can become clouded by
chemical evaporation resadue that may
cause acceptance errors.
NOTE: When closing the Acceptor or
Transport Unit’s Upper Guides, ensure that
they click firmly into place when being
closed. Also, when reassembling the
iVIZION
®
Unit, ensure that it re-seats
correctly into place when the reassembly is
complete.
a
b
1
c
d
e
b
2
Figure 2-8
Interface Harness Installation Location
Figure 2-9
M3 Screws Locations