5. Mouse-click on the “
DIP Sw ON/OFF Test
”
Screen Button (Review Figure 6-58 i) to begin
the DIP Switch ON/OFF Test.
6. Mouse-click on the “
Start
” Screen Button
(See Figure 6-65 a). The tested DIP Switch
condition will be indicated on the Screen similar
to that shown in Figure 6-65. Make sure the
desired DIP Switch Number is shown as “
ON
”.
7. Set the desired DIP Switch to
OFF
example = DIP Switch #3 and #5).
8. Make sure the desired DIP Switch Number is
“
OFF
”. (If DIP Switch #3 and #5 were set during
a previous procedure, the Screen will indicate
“ON” in each Field Window related to their DIP
Switch Number).
9. Mouse-click on the “
Stop
” Screen Button
(See Figure 6-65 b) to end the DIP Switch ON/
OFF Test.
10. Mouse-click on the “
Exit
” Screen Button
(See Figure 6-65 c) to return to the “
Test Item
Select
” Screen.
11. Turn the iVIZION
®
Power Switch
OFF
.
12. Place the Transport Unit onto the Frame.
Performance Test Tool Requirement
using an External DIP Switch Box
Figure 6-67 illustrates and list identifies the Tools
and equipment interconnects necessary to perform
the
iVIZION
®
Performance Tests using an External
Switch Box.
External DIP Switch Performance Test
Procedure Settings
Table 6-2 lists the DIP Switch settings for the
Performance Tests using the External Switch Box.
Performance Tests using the External DIP
Switch Procedures
Perform the following steps to test the Motor
Normal Forward and Reverse Rotation, the Stacker
Motor, the Cyclic Movement Test, the Status LED
Indication Test, the Banknote Transportation and
the ICB Function Setting Performance Tests.
1. Turn the iVIZION
®
Power Switch
OFF
.
2. Remove the Transport Unit from the Frame.
3. Set the desired DIP Switch Number to “
ON
”
using the 8-Position DIP Switch (See Table 6-6).
4. Place the Transport Unit back onto the Frame.
5. Connect the third the fourth Pin Connector of the
External Switch Box Cable to the corresponding
Connectors Pins of the five (5) Pin Plug located
at the rear side of the iVIZION
®
Transport Unit
NOTE: If DIP Switch #3 and #5 were set
during a previous procedure, the Screen
will indicate “
ON
” in each Field Window
related to their DIP Switch Number.
Figure 6-66
DIP Switch ON/OFF Test Screen 2
a
b
c
SW8 is Always
Performance Test
“ON” During a
NOTE: If it is necessary to perform another
test, make sure that DIP Switch No.8 is still
set to ON.
Table 6-6
Performance Test DIP Switch Settings
*
*. NOTE: The Sensor ON/OFF Test and the DIP Switch ON/OFF Test
are ONLY available when using the PC procedure!
No. Test Item
Status LED
DIP Switch Setting (O = ON)
Stand-
by
Operat-
ing
1
2
3
4
5
6
7
8
1
Motor
Normal
Forward
Rotation
Blue
Lit
Yellow
Flashes
-
O
-
-
-
-
-
O
2
Motor
Reverse
Rotation
O
O
-
-
-
-
-
O
3
Stacker
Motor
-
-
O
-
-
-
-
O
4
Cyclic
Movement
-
-
-
O
-
-
-
O
5
Status LED
Indication
Red
-
-
-
-
O
-
-
O
Green
Blue
6
Banknote
Accept-
ance
Exting-
uished
(Out)
O
O
O
O
-
-
-
O
7
ICB Setting
(Reading
Ticket)
O
-
-
O
-
-
-
O
Figure 6-67
Calibration Tool Requirements
a) iVIZION Device
b) Power Supply (12V DC - 24V DC)
c) External Switch Box
(User provided)
d) Interface Cable (3380-05-01 EDP#146780)
a
b
c
d
MOLEX 4-Pin
MOLEX 3-Pin
MOLEX 2-Pin
KF srl | www.keyfuture.com | Phone +39 059313920