17
TBV™-100/101 Units
O
PERATIONAL
E
RRORS
Operational Errors are indicated by the number of
RED
LED
flashes.
Note the number of flashes between pauses to identify the Error
Table 10
Operational Error Codes
RED
Flashes
Error Type
Cause
1
Cash Box Full
Detected a Cash Box Full condition.
2
Feed Motor Lockup
Feed Motor encoder pulses not
detected.
3
Stacker Motor Lockup Stacker Motor encoder pulses not
detected.
4
Centering Motor Lockup Centering Motor encoder pulses not
detected.
5
BNF Unit
BNF Sensors detected abnormal
movement.
6
Shutter Error
Shutter Sensors detected abnormal
movement.
7
Banknote Jam,
Pusher Mechanism
Pusher Mechanism home sensor is not
detected.
8
Pusher Mechanism
Home Sensor
The Pusher Home Sensor is not
detected.
9
Pusher Plate Half way The Pusher Plate is not returning to the
halfway position.
10
Centering Home Sensor Centering Home Mechanism is not
returning to the home position.
11
Feed Motor Speed
Motor encoder pulses out of range.
12
BNF Communications Detected communications data transfer
rate improper.
13
ICB Communications
ICB Communications abnormal.
14
Voltage
Input voltage is too low.
NOTE: Refer to the TBV
™
Series Transaction Based Validator
Operation and Maintenance Manual (JCM P/N 960-100926R)