TBV™-100/101 Units
2
QUICK REFERENCE
TROUBLESHOOTING GUIDE
O
VERVIEW
This Guide applies to the following TBV Models:
Table 2 lists Issues, Probable Causes and Possible Solutions when
troubleshooting this TBV Unit.
Table 1
TBV Model Descriptions
Device
Version Description
TBV-100 FSH
BNF, Horizontal Stack Cash Box, Centering Path
TBV-101 FSH
BNF, Horizontal Stack Cash Box, Fixed Path
TBV-100 FLD
BNF, No Cash Box, Centering Path
TBV-101 FLD
BNF, No Cash Box, Fixed Path
TBV-100 GLD
Single note, Gated Bezel, No Cash Box, Centering Path
TBV-101 GSH
Single note, Gated Bezel, Horizontal Stack Cash Box,
Fixed Path
TBV-101 ASH
Single note, JCM Standard Bezel, Horizontal Stack Cash
Box, Fixed Path
Table 2
TBV Troubleshooting Descriptions
Issue
Probable Cause
Possible Solutions
TBV Unit is not
working. (Bezel
and CPU Board
LEDs are OFF.)
Power is not
supplied to the
TBV Unit.
Check that interface connectors are
properly fitted. Verify the Power
Supply meets specification.
The program is not
active. Firmware
Download has not
completed correctly.
Re-download the correct Firmware.
The CPU Board is
malfunctioning.
Check internal Harness and
connectors. Replace the CPU Board.
The TBV is not
communicating with
the Host machine.
Interface DIP Switch
Settings incorrect.
Check the interface settings and the
DIP Switch Settings.