13
TBV™-100/101 Units
PERFORMANCE TESTING
To troubleshoot the
TBV100/101 Unit
, either the
JCM Tool Suite Appli-
cation
and/or
DIP Switch Settings
can be used.
To access the
TBV Performance Test
:
1. Set
TBV DIP Switch DS1
or
DS3 Switch 8
to
ON
.
2. Apply power to the TBV Unit (the Bezel LED flashes
White)
.
3. Connect the TBV Unit to the PC’s USB port using a Male A
to mini-B USB Cable.
4. From
the JCM Tool Suite Application
Service Mode
drop-
down menu (refer to Figure 2), click on
Performance Test
.
5. Click on the
TBV Performance Test
to be performed. To halt
the Test, click the
STOP
c
).
Figure 6
TBV Performance Test Options
NOTE: To use DIP Switch Settings, refer to the TBV
™
Operation and Maintenance Manual (JCM P/N 960-100926R).
NOTE: When an Operation Test is selected, click the Close
box “X” icon (Figure 6
d
) to halt the Test and close the screen.
c
d
a
b