TBV™-100/101 Units
20
C
ALIBRATION
E
RRORS
Refer to the following table if an error occurs during Calibration. To
determine which Sensor is in an Error Condition, look at the first two
(2) digits to determine when the error occurred. Then check the Vali-
dation Sensor Error Codes (Table 12) for details about the Error.
Table 12
Validation Sensor Error Codes
Sensor Calibration
Digit
Number
Error Code Format
Validation Sensor
[D/A Value, non-Paper]
16 digits 01-YYYY-YYYY-YYYY-YYYY
*
* Refer to Table A-6 and A-7 in the TBV™ Series Transaction Based Validator Operation and Maintenance Man-
ual (JCM Part No. 960-100926R) for Sensor Flag Values indicated in the “YYYY-YYYY-YYYY-YYYY” or “zz-zz-
zz” formats.
Validation Sensor
[with the Reference Paper]
16 digits 02-YYYY-YYYY-YYYY-YYYY
*
Validation Sensor
non-Paper
16 digits 05-YYYY-YYYY-YYYY-YYYY
*
UV (Reflection) Sensor
with paper
8 digits
03-000-000
UV (Transmissive) Sensor
with paper
8 digits
04-000-000
UV (Transmissive) Sensor
non-paper
8 digits
06-000-000
Bar Sensor
8 digits
07-zz-zz-zz
*
String Detection Sensor
8 digits
08-000-000
Positioning Sensor
8 digits
09-zz-zz-zz
*