P/N 960-100928R_Rev. 3 {EDP #192692}
© 2018, JAPAN CASH MACHINE CO., LTD.
2 - 8
Section 2
UBA-RC™ Series Banknote Recycler
Installation
Caution: DO NOT use alcohol, solvents,
abrasive cleaning agents, or citrus-
based cleaners that can damage the
plastic surface of the device when
cleaning it. The lenses can become
clouded by chemical evaporation
residue that may cause acceptance
errors.
Caution: Be sure to use non-flammable
compressed air only.
NOTE: When closing the UBA’s Transport
Unit or the Recycler Unit’s Upper Guides,
ensure they firmly click into place when
closed. Also, when re-assembling the UBA-
RC Unit, ensure that it re-seats correctly
into place when reassembly is complete.
NOTE: Wipe and clean all of the
Green-
colored Rollers and Belts shown in Figure
2-10 on page 2-9 using a slightly damp (not
wet), lint-free Micro-fiber cloth.
Caution: DO NOT let liquids or fluids
drip into the Unit’s interior; otherwise,
the Unit may not operate correctly.
NOTE: Cleaning the Pick Roller should be
performed only when appropriate Operator
training has been completed!
Figure 2-9
Figure 2-9
Sensor and Roller Cleaning
Lens
Roller
Lint-free Cloth/Cotton Swab/Air
Before
Cleaning
After
Cleaning
Belt