JCM Part No. 960-000097R_Rev. 3
© 2010, JCM American, Corporation
1 - 2
Section 1
Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU)
General Information
Model/Type Number Specifications
Precautions
The Figure 1-2 symbols are defined as follows:
1. (
Type 1
) Do not insert a torn, folded, or wet
Banknote, as this action may cause a Bank-
note jam inside the unit.
2. (
Type 2
) Do not expose the unit to water.
The unit contains several precision elec-
tronic devices which can be damaged if
water or any liquid is sprayed or spilled into
the unit.
3. (
Type 3
) Do not install the unit into a dusty
environment. Dust may affect and degrade
the sensor’s performance.
User Cautions
1. Be sure to turn the power off before plugging
or unplugging connectors.
2. Firmly close the Unit’s Transport path before
applying power.
3. When closing the Unit, ensure all service
door locks click into place. Make sure to
open and close the Unit’s Banknote path
access ports gently, and take care that no dust
or other foreign objects enter when opening
the guide area.
4. Do not allow inventory stock to endure high
temperature, high humidity or a dusty
environment.
5. Do not throw the Unit or drop it to the
ground. Improper handling may cause per-
sonal injury and/or damage to the equipment.
6. When opening the Upper Guide, hold the
guide up since it does not stay in the open
position by itself.
7. If the Bill Validator is dirty due to dust,
foreign objects, or other such debris adhering
to it, Banknote acceptance rate will degrade.
Table 1-1:
Model Number Specifications
N
o
Model: UBA - ** - S* - **0 - 00 - ***** - *** - **
N
o
(1,2) (3) (4,5,6) (7,8) (9,10,11,12,13) (14)(15)
(1)
Sensor Configuration
(2)
CPU Board Type
(3)
Stacking Configuration
SS = Security Stacker (Downward vertical stacking
[standard])
SU = Stack Upward (Upward vertical stacking)
(4)
Cash Box Capacity
(5)
Cash Box Type/Color
0 = Black Plastic
S = Steel (WBA Style Box)
(6)
Cash Box Handle Type/Color
(7)
Transport Unit Body Color
0 = Black w/Blue Cover (standard)
(8)
Transport Unit Cover Color
0 = Blue (standard)
(9)
Faceplate
*
0 = Without Faceplate (standard)
1 = With JCM Standard UBA Faceplate (85mm wide)
2 = With Blue/Blue LED
A = With Blue/Blue LED (2-line)
*. Contact your JCM Sales Representative for information concerning
Faceplates, the ICB and other options available.
(10)
Intelligent Cash Box (ICB Option)
0 = ICB not supported (no ICB Board or ICB Cash Box)
1 = ICB supported (with ICB Board & ICB Cash Box)
2 = ICB supported (with ICB Board & UBA Cash Box)
(11)
External Interface Board (Optional)
0 = Standard (no external I/F Board)
1 = With 24V - 13.5V + Rs232C I/F Conversion Board
2 = With RS232C I/F Conversion Board
3 = With cc-Talk I/F Communications Board
4 = With 24 VDC/13.5 VDC & USB I/F Conversion Board
(12)
Input/Output signals
F = Photo-coupler Isolation
R = RS232C
(13)
Harnessing (External)
0 = No Harness
1 = Standard Harness
2 = OEM Harness
F = 24VDC/13.5VDC Conversion Harness (w/Photo
Coupler)
R = 24VDC/13.5VDC Conversion Harness (w/RS-232C)
(14)
Accepted Country Code
ISO 3166-based 3-digit Alpha Code (See page 1-15).
(15)
Interface
†
†. Contact your JCM Sales Representative for information concerning
other interface styles.
1. Security-Stacker (SS)
2. Up-Stacker (SU)
0. 8Mbit Flash ROM
1. 8Mbit EPROM
2. 16Mbit Flash ROM
4. USB interface
applicable
5 = 500 Note Capacity
9 = 900 Note Capacity
0 = Blue Plastic (standard)
1 = Red Plastic
J = Steel (WBA)
N = None (WBA)
03 = JCM ID-003 Serial
Interface
24 = OEM Interface
28 = OEM Interface (USB)
Type 1
Type 2
Type 3
Figure 1-2
Precautionary Symbols
Do NOT carry the UBA Unit by the
Cash Box handle, it can release
and drop the Unit to the ground
causing physical damage.