JCM Part No. 960-000097R_Rev. 3
© 2010, JCM American, Corporation
6 - 1
UBA® Series
Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU)
S e c t i o n 6
This section provides Flash Memory Download
Programming, Calibration, and Performance Test-
ing instructions for the Universal Bill Acceptor
(UBA) Series. This section contains the following
information:
•
Workbench Tool Requirements
•
Software Download Preparation
•
Software Downloading Procedure
•
Programming Instructions
•
Calibration Procedures
•
Performance Tests
Workbench Tool Requirements
The following tools are required to perform a
Workbench Software Download (See Figure 6-2):
•
JCM Universal Bill Acceptor (UBA)
•
JCM External Power Supply (Part No. 701-
000148) or equivalent
•
PC containing a USB port (OS: Windows
2000/XP)
•
USB Cable (A type Male to B Type Male)
(See Figure 6-1).
•
The latest .ZIP compressed UBA Download
Program (V1.11 or later).
Software Download Preparation
The following instructions describe how to decom-
press and store a downloaded program onto a
personal computer (PC) for eventual installation
into the Universal Bill Acceptor:
1. Refer to the Figure 6-2 interconnection
diagram to properly connect the various
cables and wiring harnesses to the UBA.
6 PROGRAMMING, CALIBRATION & TEST
Figure 6-1
Download USB Cable Requirement
Figure 6-2
Required Download Workbench Tools