JCM Part No. 960-000097R_Rev. 3
© 2010, JCM American, Corporation
6 - 4
Section 6
Universal Bill Acceptor (UBA-1x-SS & UBA-x4-SS/SU) Programming, Calibration & Test
Forced Download Requirements
If the UBA does not accept a download in th nor-
mal manner as previously described, a Forced
Download may be required. To perform a Forced
Download, proceed as follows:
1. Remove Power from the UBA Unit.
2. Turn Dip Switches #6, #7 & #8 ON.
3. Apply Power from the UBA Unit. An active
Forced Download Mode will be indicated by
the two (2) LEDS (Red & Green) will be
alternately blinking.
4. At this point, proceed with the previously
described Normal Downloading Proceedure.
Calibration Procedures
Calibration Description
Calibration sets a starting reference point for all
optical and magnetic sensors within the unit.
This task can be accomplished at the host unit or at
a workbench.
Calibration Tool Requirements
The following equipment and tools are required for
workbench calibration: (See Figure 6-13).
•
JCM Universal Bill Acceptor (UBA)
•
JCM External Power Supply (JAC Part #701-
000148) or equivalent
•
PC containing a USB port (OS: Windows
2000/XP)
•
White Reference Paper (JAC Part #501-
000167R, EDP #107724)
•
Black Reference Paper (JAC Part #501-
000166R, EDP #107725)
•
UV Reference Paper (JAC Part #501-
000164R, EDP #110664)
Figure 6-11
PC Browse Screen
Figure 6-12
Installation Complete Screen
NOTE: Once the software is downloaded
into the UBA, it is recommended that
Banknote acceptance be tested using the
new software to confirm that the download
was successful. (See Test “No. 8 Bill
Acceptance Test” on page A-11 of
Appendix A regarding Bill Acceptance
Testing).
Figure 6-13
Required Calibration Workbench Tools