PC supported adjustment
This procedure is more complex than the quick adjustment, but it does provide more
reliable results, as all sensors are calibrated.
When possible you should use this method!
You need the following accessories for the PC supported adjustment:
MIB232
Black Reference Paper (KS-0… )
White Reference Paper (KS-0 …)
Mag-Tool
MG-03
JCM Adjustment Software
Methodology
1.
turn off the electricity
2. turn on position 8 of the dipswitch .
3. turn on the electricity.
4. wait until both LED lights on the CPU board are switched on
Fig. 12