5.
Adjustment of the reciver / Operating modes
Autocheck period
SW1
7 s
The system performs a complete test of the equipment, including
radio communication.
30 s
Operating mode with optical safety edges
SW2
ON
In ON mode, only "always on" optical safety edges (OSE-S7502)
are permitted, as the optical element always is on.
In WORK mode, the optical elements are OFF meanwhile the
ATEST signal is active. So it is necessary to disconnect this ATEST
signal during the door movement.
WORK
Inhibition polarity
SW3
Open
contact
Open contact in “INH-GND” connector
switch off NO TOUCH detector.
Close contact in “INH-GND” connector
switch off NO TOUCH detector (CAP MAGIN)
Close
Contact
ATEST signal polarity (depends on the control panel)
SW4
Negative
ATEST negative:
ATEST signal is a fixed 12 or 24V signal that the
control panel sets to 0V to make the system check.
ATEST positive: ATEST signal is disconnected and when the control
panel makes a testing gives a 12 or 24V signal.
Positive