background image

  

18

7

 Receivers allowed for the groups

Free

applications manual for Free system

Resume of receivers which can work with FREE system GROUPS

be a step ahead with technology and imagination

jcm

technologies

RECEIVERS

MOTION JCM

Receiver

Applications

Description

Compatible with 

GROUPS system

BASE30

868 MHz radio 
receiver, 1 or 2 
relays, 30 codes.

1 impulse relay channel. / 2 channel (Relay 1 impulse 
and relay 2 selectable impulse/bi-stable).
Built-in antenna.
Fixed 30 code memory.
Power supply: 12/24Vac/Vdc

Transmitter group 
self-learning

BASE500

868 MHz radio 
receiver, 1 or 2 
relays, 500 codes.

1 impulse relay channel. / 2 channel (Relay 1 impulse 
and relay 2 selectable impulse/bi-stable).
Built-in antenna.
Removable 500-code memory.
Power supply: 12/24 Vac/Vdc.

Compatible 
with groups        

STICK30

Pluggable receiver 
card, 2 channels,
30 codes.

2 channel (Relay 1 impulse and relay 2 selectable
impulse/bi-stable).
Built-in antenna.
Fixed 30 code memory.Pluggable in control panel.
Power supply: 12Vdc from the panel.

Transmitter group 
self-learning

STICK500

Pluggable receiver 
card, 2 channels,
500 codes.

1 impulse relay channel (modificable a biestable con 
herramienta de programación ASSISTANT).
Built-in antenna.
Removable 500-code memory.
Pluggable in control panel.
Power supply: 12Vdc from the panel.

Compatible 
with groups

ST500

Active antenna with 
built-in 868 MHz.

2 impulse relay channels

 

(can be modified to bi-stable 

using the ASSISTANT programming tool).
Removable 500-code memory.
Antenna connector.
Dead-man program for transmitters which work this way.
Pluggable in ASSISTANT and PROGMAN programming 
tools

.

Group self-learning

CONNECT

Multi-protocol 
868 MHz radio 
receiver.

Allows for the use of 868 MHz transmitters with any 
control panel operating with Wiegand or Clock&Data 
protocol.
Allows for single or multi-channel configuration.
Power supply: 12Vdc.
Anti-passback input.
Built-in antenna.

Group self-learning

ACTIVA GO

Active antenna with 
built-in 868 MHz.

Allows for the reception points to be multiplied and to 
increase the range of the system, connecting several 
antennas in parallel. 
Works as a buffer, receiving codes and re-transmitting 
them to the receiver by cable.
Can be used as an interface with DCS equipment.
Power supply: 12Vdc.
Maximum cable length: 200 m.

Group self-learning

RBMOTION

Radio communication 
system for safety 
bands with built-in 
MOTION 868 MHz 
receiver.

Equipment comprising:
RADIOBAND receiver (2 relays with selectable operating 
mode. Can behave like a safety edge or a closed safety 
contact).
6-RADIOBAND/TBX transmitter memory. 
MOTION 868 MHz receiver (2 relays ( Relay 1 impulse 
and relay 2 selectable impulse/bi-stable), fixed 30 code 
memory.
Power supply: 12/24Vac/dc.

Transmitter group 
self-learning

Summary of Contents for Free30r

Page 1: ...lectronic solutions for gates doors and access control Free hands free system for vehicles and people Applications manual for Free system be a step ahead with technology and imagination jcmtechnologie...

Page 2: ...be a step ahead with technology and imagination jcmtechnologies...

Page 3: ...T 12 4 Programming 13 4 1 Tag Programming in the Receiver 13 4 2 Trigger Programming 14 5 Applications 15 5 1 Applications in shops and catering 15 5 2 Applications in offices 15 5 3 Industrial applic...

Page 4: ...and even industrial ve hicles and for individual use by pedestrians in private and professional areas allowing for the access control of people and goods FreeTH is a multi use product especially desi...

Page 5: ...low battery signal transmission and programming Push button inlet for voluntary activations Operating temperature 20 C a 55 C ABS plastic case Size 65 x 55 x 10 mm Nominal range 100 meters Transmissi...

Page 6: ...etres Free50rs nominal range 5 metres Fitted with an adjustable presence sensor capable of detecting a moving body from 2 5 to 6 5 metres Transmission frequency 125 KHz Power 230Vac LED operations ind...

Page 7: ...orporated into the cabling This equipment must always be installed in a vertical position and firmly fixed to the structure of the building This equipment can only be handled by a specialist fitter by...

Page 8: ...l or magnetic detector they must be connected the pre sence cable and the mass cable see Installation section In that way when the detector detects presence the trigger starts trasnmitting and the Tag...

Page 9: ...ill activate the outputs The difference between both ways of functionning of Free system lies on the quantity of information is transmitted by the TAG to the receiver While working as hands free trigg...

Page 10: ...4x310 5x41 6 mm Free50r and 394 4x310 5x78 7 mm Free50rs This allows Free15r to be installed in a standard electric box either wall mounted as built in both interior or exterior of the installation To...

Page 11: ...e50rs triggers must be connected in series and a maximum of 4 can be connected In order to get a proper funtioning OUT sincronism signal must be connected to IN sincronism signal until the last trigge...

Page 12: ...that the car holder is placed in the windshield we recommend to allocate it in the dotted area to guaranty a better range in athermal windows To place the TAG in Car Holder only slide the Tag through...

Page 13: ...the Tag to activate itself The TAG emits the information to the receiver together with a whistle that confirms Tag programming in the receiver To finish this operation you can either press the Prgo b...

Page 14: ...of the trigger must be pressed Led will show the red slowly blinkings of the channels configuration But we must keep pressing then led will show green blinkings in a really fast way This meants that...

Page 15: ...5 2 Application in Industry 5 3 FreeT has been though to be used in applications such residential community shopping offices restaurants industry institu tions and twon planning FreeTH has been though...

Page 16: ...6 5 Applications Free applications manual for Free system 5 4 Application in barriers 5 5 Application in residential and community doors be a step ahead with technology and imagination jcmtechnologies...

Page 17: ...s Do not install the trigger in metallic surfaces If so the range can be affected To change the batteries every 18 months or at least when the Tag point it out by acustic or lighting signal As in GoPr...

Page 18: ...ply 12Vdc from the panel Compatible with groups ST500 Active antenna with built in 868 MHz 2 impulse relay channels can be modified to bi stable using the ASSISTANT programming tool Removable 500 code...

Page 19: ...ory Power supply 230 V o 12 24 Vac Vdc Acces control input Non compatible with groups ACCESS500 Stand alone access control 1 channel being extendible to 4 channels 500 codes Impulse bi stable relay ch...

Page 20: ...tecnolog a imaginaci n jcm tech...