P/N 960-000180R_Rev. 1 {EDP #233427}
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 6
Section 6
DBV® Series DBV-400 Banknote Validator
Calibration and Testing
5. Hook the KS-095A Reference Paper Tabs into
both sides of the Cut-out Space on the DBV-400
Unit (Figure 6-27
c
).
6. Place the KS-095A Reference Paper
) in the center of the Transport Path
to ensure the Inside Sensors are covered by the
Reference Paper as shown in Figure 6-28
a
.
7. Firmly set the Validation Guide (Figure 6-29
a
)
while adjusting the KS-095A Reference Paper
b
) placement location until the
Guide “clicks” into place, and ensure that it is
tightly locked.
8. Pull the KS-095A Reference Paper (Figure 6-29
b
) just slightly in the direction indicated by the
red arrow
A
until the Reference Paper is taut.
NOTE: Make sure that the Reference
Paper Tabs are firmly hooked into the
Cut-out Space.
Figure 6-27
Figure 6-27
Placing KS-095A Reference Paper 4
Cut-out Space
b
a
c
Figure 6-28
Placing KS-095A Reference Paper
Figure 6-28
Placing KS-095A Reference Paper 5
a
b
Figure 6-29
Figure 6-29
Placing KS-095A Reference Paper 6
b
A
a
NOTE: Make sure that the Guide Chip A
a
) and Guide Chip B (Figure
b
) are set back in the DBV-400 Unit
after calibration is complete.