P/N 960-000180R_Rev. 1 {EDP #233427}
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 1 4
Section 6
DBV® Series DBV-400 Banknote Validator
Calibration and Testing
Performance Test Without a PC
To perform the Aging Test, proceed as follows:
1. Remove electrical power from the DBV-400 Unit.
2. Set the DBV-400 DIP SW1 #4 and #8 to
ON
(Figure 6-63) and the all DIP SW2 switches to
OFF
3. Connect the Power Harness and apply electrical
power to the DBV-400 Unit.
4. To start the Aging Test, set the DBV-400 DIP
SW1 #8 to
OFF
5. DIP SW1 #6 and #7 can be used to change inter-
val timing of the Aging Test. (See Table 6-5
Aging Test Interval Timing Settings for Switch
#6 and #7 settings for each interval.)
6. Place the Cash Box onto the DBV-400 Unit to
begin the aging movement.
7. Remove the Cash Box and set the DIP SW1 #8 to
ON
to end the Aging Test.
This completes the Aging Test.
Table 6-4
Performance Test Items and DIP Switch 1 Settings
Test Item
DIP Switch 1 Setting
Test Purpose
*
1
2
3
4
5
6
7
8
†
Feed Motor Normal Rotation
ON
ON/OFF
Speed Check while Normal Rotation
Feed Motor Reverse Rotation
ON
ON/OFF Speed Check while Reverse Rotation
Stacking
ON
ON/OFF
Stacking Mechanism Movement
Check at 3 seconds intervals
Aging Test
‡
ON
ON/OFF
Aging Movement Check at intervals
set by DIP SW1 #6 & #7
Sensor Test
ON ON/OFF
Each Sensor Performance Check
Acceptance Test
†
ON ON
ON
ON
ON/OFF
Acceptance Check with Validation
Acceptance Test
†
ON ON
ON
ON
ON
ON/OFF Acceptance Check without Validation
Reject Test
†
ON ON
ON
ON
ON
ON ON/OFF
Reject Check without Validation
DIP Switch 1 Test
ON ON
ON
ON
ON
ON
ON ON/OFF
DIP Switch 1 (SW1) Performance
DIP Switch 2 Test
ON
ON
ON
ON
ON
ON ON/OFF
DIP Switch 2 (SW2) Performance
Bezel LED Test
ON
ON
ON
ON ON/OFF
Bezel LED Performance Check
Push Button Test
-
-
-
-
-
-
-
-
Push Button Performance Check
*. If any errors occur, refer to Table A-4 “LED Flash Error Codes” on page A-3.
†. DIP SW1 #8 Setting; ON to standby or stop test, OFF to start test.
‡. This test is available when the Cash Box is correctly in place.
See “Workbench Tool Requirements Without a PC” on page 6-1 for the Tools and Equipment
interconnects necessary to perform a DBV-400 performance Test without a PC.
Table 6-4 lists the items and DIP Switch 1 (
DIP SW1
) settings for the DBV-400 Performance Test.
Aging Test
Figure 6-63
Aging Test DIP SW1 Setting
ON
1
2
3
4
5
6
7
8
Figure 6-64
Aging Test DIP SW2 Setting
ON
1
2
3
4
5
6
7
8
Figure 6-65
DIP SW1 #8 OFF
ON
1
2
3
4
5
6
7
8
Table 6-5
Aging Test Interval Timing Settings
DIP Switch 1
Interval
#6
#7
OFF
OFF
30 seconds
ON
OFF
1 second
OFF
ON
2 seconds
ON
ON
10 seconds
ON
1
2
3
4
5
6
7
8