179
Also in case of External PLU it's possible to visualize on display the PLU's data
(residents on the PC or on the memory box) also during the receipt execution, without
therefore the receipt must be close to being able to set the ECR in S mode. By the following
described procedure it will be possibile to visualize on ECR's display the description and the
price of the wished PLU.
In order to activate the function of external PLU control to execute :
-
During a receipt.
-
To press the PLU INFO key.
-
Call the PLU code by :
(NNN..N) PLU
NNN..N
=
PLU code
Note:
The sequence (NNN... N) PLU can be replaced from the reading through
scanner of the product's bar-code or from the pressing of direct PLU key
-
On the ECR's display it will be visualized the description and the selling price of
the PLU.
-
To continue with the successive registrations.
16.6
TRAINING MODE
It's possible to activate an instruction modality that allows to operate on the ECR
without that no totalizers and counters comes be modified by the configuration of the
S.S.5B, also the eventual external device to which the ECR can be connected is in condition
to recognizing such operating modality.
Such operativity must obviously submit to some rules to be activated.
The first one and the more important of such ties is that the ECR allows the training
operating modality only like first operation after the execution of one Daily full terminal
report (Z--1--Tot.1) ; therefore if after the Daily full terminal report” (Z--1--Tot.1) is executed
on the ECR an operation that is not that one to go in training modality (even if programming
or not selling receipt printing, Eg.: P/O or R/A operations), the ECR will not allow (until the
next Daily full terminal report execution) to activate the training operating mode signaling
the error E174 - Inhibit Training.
It's important to hold in consideration also that after the Daily full terminal report it will
be possible to go in training mode for one time only.
Another important tie is that determines the format of
the receipts printed in this modality, than for obvious reasons
cannot to be confused with normal receipts printed from the
ECR (sees example).
-
"Z" mode
-
To input 9999.
-
To press the Key key.
-
To operate with the normal registrations on
the ECR.
-
In order to exit from such modality to press
on the ECR 1--Key to go in Reg. mode.
t