GAMMA VERSUS MANUAL
30
COD. 1257066 Gamma VERSUS Manual v1.13
7.3 Pedestrian function
Model
All
Associated
parameters
ID
Description
Type
P37
Open Ped. stop point
NUMERIC
P38
Close Ped. stop point
NUMERIC
Description
VERSUS control panels can control 2 types of maneuvers: main and pedestrian
maneuvers. The aim of the pedestrian maneuver is opening a portion of the door in order
to let enough space to allow entering/exiting a person, without the need to open the hole
door.
Configuration
The pedestrian mode is enabled by default and it is necessary to program its maneuver
in the same way the main maneuver is programmed (except if autoprogramming function
is enabled). The only difference is that the pushbutton needed to program the pedestrian
maneuver is the PEDESTRIAN pushbutton.
Operating
After programming the pedestrian maneuver, if a PESESTRIAN pushbutton is pressed
the pedestrian maneuver is executed and the door opens the portion of the programmed
aperture.
Notes
The pedestrian maneuver parameters that define its duration are the
P37
and
P38
configuration parameters. The opened and closed positions are the starting points and
they always take the 0 value.
P37
parameter configures the opening stop point (opening
pedestrian maneuver duration) and the
P38
parameter configures the closing stop point
(closing pedestrian maneuver duration).
P37
Open
Ped.
stop
point
Open
Ped.
starting
point
(always
0)
P38
Close
Ped.
stop
point
Close
Ped.
starting
point
(always
0)
Summary of Contents for GAMMA VERSUS Series
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...