GAMMA VERSUS MANUAL
31
COD. 1257066 Gamma VERSUS Manual v1.13
7.4 Speed regulation and slow speed mode in AC motors function
Model
M20,M30, M22
Associated
parameters
ID
Description
Type
P04 Slow
speed
ON/OFF
P46
Norm/Low speed factor
NUMERIC
P94
AC Motor speed regulation
NUMERIC
P95
AC Motor low speed regulation
NUMERIC
P35
Open slow start pt.
NUMERIC
P36
Close slow start pt.
NUMERIC
P39
Open Ped. Slow start pt.
NUMERIC
P3A
Close Ped. Slow start pt.
NUMERIC
PCD
Open slow start pt. motor 2 (M22)
NUMERIC
PCE
Close slow start pt. motor 2 (M22)
NUMERIC
Description
Some VERSUS control panels for AC motors allow controlling motor speed during the
maneuver (normal speed regulation and slow speed mode).
Configuration
By default, the normal speed regulation function is enabled. This configuration parameter
P94
allows modifying the normal speed regulation and it can take any value from 10% to
100%. The smaller the value, the slower the normal speed. This configuration parameter
can be configured by means of VERSUS-PROG programming tool.
To enable slow speed mode it is necessary to set to ON the associated
P04
parameter
by means of a VERSUS-PROG programming tool. It is also possible to enable or
disable this function by setting the slow speed mode ON/OFF function to an option
switch.
There are two configuration parameters that allow modifying the slow speed: The
P46
parameter is used to adjust, in a coarse way, the normal/slow speed factor and it can
take values from 0 to 255. The higher the value, the slower the slow speed according to
the normal speed. The
P95
parameter allows modifying the slow speed regulation, doing
a fine adjustement, and it can take values from 0% to 90%. The higher the value, the
slower the slow speed. Depending on the AC motor model these parameters will be
needed to be adjusted in order to obtain the desired slow speed. This adjustment must
be done with the AC motor connected to the door (full charge).
Summary of Contents for GAMMA VERSUS Series
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...