Section 6
iPRO-RC™ Series Banknote Recycler
Performance Tests
Individual Calibration and
Performance Test
This section explains the individual Calibration and
Performance Testing Procedures for each Sensor
within an iPRO-RC™ Unit. (Review “Sensor Cali-
bration and Performance Testing” on page 6-5 of
this Section for complete DIP Switch Settings).
Sensor Test Screen
Individual calibration and testing is available when
the “
iPRO-RC Maintenance Tool
” is in the Sensor
Test Mode. To change the Mode, proceed as
follows:
1. Click on the “
iPRO-RC Maintenance Tool
” Tool
Bar’s “
Mode
” pull-down Menu, and select “
Sen-
sor Test
” from the selections available (Figure 6-
a
).
2. The Test Function Screen shown in Figure 6-49
will appear. Confirm that the each Screen Button
Function and its related Status Cell indication
contains a result.
Individual Calibration
The following four (4) Function Buttons are used to
perform these related Calibrations:
•
Load Sensor Data
•
Double Note Detection Sensor
•
RC Full Sensor
•
Save Sensor Data
L
OAD
S
ENSOR
D
ATA
1. Click on the “
Load Sensor Data
”
Function Screen Button (Fig-
a
) to read the current iPRO-RC™ Sensor
Data.
2. Confirm that the iPRO-RC™ Unit’s LED indi-
cates a steady
Green
Color. The Bold Text “
Pro-
cessing
”
word appears during the
Test’s performance (Figure 6-51
b
).
3. When reading current data is complete, the Bold
Text “
Processing
”
word will turn to
Grayed-out text (Figure 6-51
b
), and a “
Load OK
”
text message will appear in the related Status
result Field (Figure 6-51
c
).
D
OUBLE
N
OTE
D
ETECTION
S
ENSOR
C
ALIBRATION
1. Insert a piece of KS-087 Reference Paper into the
iPRO™ Transport Unit Insertion Slot.
2. Click on the “
Double Note Detection Sensor
”
Calibration Screen Button
a
).
3. Confirm that the iPRO-RC™ Unit’s LED indi-
cates a steady
Green
Color. The Bold Text “
Pro-
cessing
”
word will re-appear
during Performance Testing (Figure 6-52
b
).
4. When Double Note Detection Sensor Calibration
is complete, the KS-087 Reference Paper will be
returned, and the Bold Text “
Processing
”
Figure 6-48
Figure 6-48
Sensor Test Selection
a
Figure 6-49
Figure 6-49
Test Function Listing Screen
a
b
c
d e
a) Calibration Result Indication Field
b) Performance Test Result Indication Field
c) “Processing” Indication
d) Performance Test Function Buttons
e) Calibration Function Buttons
Figure 6-50
Calibration Test Function Screen
Figure 6-50
Calibration Test Function Screen
Buttons
NOTE: Always read the Sensor Data first
prior to starting one of the two (2) Sensor
Calibration Procedures.
NOTE: The LED will flash at a
Green
Color Rate when an abnormal condition
occurs!
Figure 6-51
Figure 6-51
Load Sensor Data
c
b
NOTE: The LED will flash at a
Green
Color Rate when an abnormal condition
occurs!