CONFIDENTIAL PROPERTY OF JCM GLOBAL
© 2010, Japan CashMachine Co, Limited
3
iVIZION™ Series Next-Generation Banknote Acceptor Integration Guide
2 SPECIFICATIONS
Technical Specifications
Environmental Specifications
Electrical Specifications
Table 1
iVIZION Technical Specification
Banknote Types Accepted:
Long edge: 110-170 mm (4.33-6.69 in.)
Short edge: 60-85 mm (2.36-3.35 in.).
Barcode Coupon
*
*. Refer to the specific Country’s “Bar Code Coupon Specification” for more details.
Standard Specification
a) Read Code interleaved: 2 of 5
b) Narrow Bar: 0.5mm-1.0mm (0.19-0.23 in.)
c) Wide Bar: Narrow Bar = 3 : 1
d) Characters: 18 Characters
e) Print Position: Middle (by dividing a Coupon equally on the left, right, top and
bottom of the Coupon’s exact center)
f) Print Width: Wider than 10mm (0.39 in.).
Insertion Direction:
Refer to the specific Country’s Software Information Sheet.
Processing Speed:
Approximately 2 seconds from Banknote insertion to Vend signal output.
Approximately 3 seconds from Banknote insertion to completion of the
stacking operation.
Validation Method
Optical
Diagnostic Indicators:
Power LED, Status LED, Bezel LED (Optional)
Escrow:
1 Note
Cash Box Type
†
:
†. User supplied installed Locks (including the attached Plate, Lock and Key).
Secure Cash Box
Intelligent Cash Box (available with RF-ID Specification)
Cash Box Capacity
‡
:
‡. The number of Notes stacked depends on the Banknote’s condition.
Standard: 500 Banknotes
Large: 900 Banknotes.
Fraud Detection:
Equipped
Interface:
USB Interface: USB Specification Rev.2.0 Hi Speed Transfer (480 Mbps)
Serial Interface: Photo-Coupler Isolation
Serial Interface: RS232 Communication Protocol.
Table 2
iVIZION Environmental Specification
Operating Temperature:
5º C to ~ +50º C (41º F to ~ 122º F)
Storage Temperature:
-20º C to ~ +70º C (-4º F to ~ 158º F)
Relative Operating Humidity:
15% to ~ 85% RH (non-condensed)
Relative Storage Humidity:
15% to ~ 85% RH (non-condensed)
Installation:
Indoors Only
Table 3
iVIZION Electrical Specifications
Supply Voltage:
12V DC (-10%) ~ 24V DC (+10%)
Current Consumption:
Standby: 24V DC = 0.2A, 12V DC = 0.2A
Operation: 24V DC = 1.3A, 12V DC = 2.3A
Maximum: 24V DC = 3.2A, 12V DC = 3.0A
Hydrothermal Condition Table
[°C]
[RH%]
Allowable Operating
Temperature and
Humidity Range
40°C/85%
60°C/40%