background image

CONFIDENTIAL PROPERTY OF JCM GLOBAL 

DRAFT 

5

 © 2010, Japan CashMachine Co, Limited

9

iVIZION™ Series Next-Generation Banknote Acceptor Integration Guide

 

I

VIZION I

NSTALLATION

/M

AINTENANCE

 S

PACE

 R

EQUIREMENTS

Figure 9 illustrates the iVIZION™ installation and maintenance and space requirements.

NOTE: All Dimension are in Millimeters

Figure 9 

iVIZION Installation and Maintenance Space Requirements Diagram

NOTE: If a maintenance space clearance 
area is unavailable, the iVIZION™ Unit will 
need to be dismounted when maintenance 
procedures need to be performed.

Caution: When installing the iVIZION 
Unit into a Host Machine, do not tilt it 
downward more than 50 degrees from a 
Horizontal position (See Figure 10
).

Figure 10 

Maximum Gradient Angle = 50 Degrees

Summary of Contents for ivision series

Page 1: ...5 2010 Japan CashMachine Co Limited iVIZION Series Next Generation Banknote Acceptor Integration Guide Revision A May 5 2010 CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT RELEASE FOR OEM INTEGRATION USE...

Page 2: ...n Banknote Acceptor Integration Guide CONFIDENTIAL PROPERTY OF JCM GLOBAL REVISION HISTORY Rev Date Reason for Update Comment A 05 05 10 Initial Document 1 2 Contains Transmitter Module FCC ID VZQNRWA...

Page 3: ...ON 4 Installation Procedure 4 Installation Process 4 Cable Interconnection 5 DIP Switch Configurations 5 Primary LED Indications 5 Cleaning Procedure 6 4 VARIOUS IVIZION UNIT DIMENSIONS 8 iVIZION Enti...

Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK iVIZION Series Integration Guide Table of Contents CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited ii...

Page 5: ...M4 Screws Locations Left Right Side 4 Figure 5 Flat Head Screws Locations Rear Side 4 Figure 6 Cable Interconnection 5 Figure 7 iVIZION Sensor Cleaning Locations 6 Figure 8 iVIZION Banknote Acceptor U...

Page 6: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited iv THIS PAGE INTENTIONALLY LEFT BLANK iVIZION Series Integration Guide List of Figures...

Page 7: ...N Environmental Specification 3 Table 3 iVIZION Electrical Specifications 3 Table 4 iVIZION Structural Specifications 4 Table 5 Denomination INHIBIT DIP Switch Settings 5 Table 6 JCM Private Line DIP...

Page 8: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited vi iVIZION Series Integration Guide List of Tables THIS PAGE INTENTIONALLY LEFT BLANK...

Page 9: ...scription Precautions Specifications Unit Dimensions International Compliance Technical Contact Information In order to make operation of this device easier and make navigation within this manual simp...

Page 10: ...ng H DIP Switch Block Denomination INHIBIT I DIP Switch Block JCM Custom Private Line J Acceptor Unit Release Pushbutton K Status LED Four 4 Colors Red Yellow Green Blue L Front Panel Bezel JPL Connec...

Page 11: ...to completion of the stacking operation Validation Method Optical Diagnostic Indicators Power LED Status LED Bezel LED Optional Escrow 1 Note Cash Box Type User supplied installed Locks including the...

Page 12: ...uration is preferred bolt the left and right side of the iVIZION Frame into its intended location using six 6 M4 Screws on both sides of the Frame 3 Screws on each side as shown in Figure 4 3 When an...

Page 13: ...Resistance Open RS 485 Terminating Resistance Closed a b c d a iVIZION Unit b Interface Connector iVIZION c Harness d Host Machine Game Machine Jute Box Kiosk etc Figure 6 Cable Interconnection SW1 J...

Page 14: ...is free of contaminants Sensor Cleaning Procedure 1 Turn the iVIZION Unit Power OFF 2 Clean the Sensors and lenses in the Acceptor Unit the Transport Unit and on the Cash Box itself If necessary remo...

Page 15: ...ors Wipe area clean using a lint free cloth such as a Micro Fiber Cloth or blow clean using Compressed Air b Exit Sensors c UV Sensor Upper d UV Sensor Lower e Transmissive Sensor f CIS Sensor Upper g...

Page 16: ...ies Next Generation Banknote Acceptor Integration Guide 4 VARIOUS IVIZION UNIT DIMENSIONS iVIZION Entire Unit Outside Dimensions Figure 8 illustrates the iVIZION Unit s entire outside dimensions Figur...

Page 17: ...ce requirements NOTE All Dimension are in Millimeters Figure 9 iVIZION Installation and Maintenance Space Requirements Diagram NOTE If a maintenance space clearance area is unavailable the iVIZION Uni...

Page 18: ...iVIZION Series Next Generation Banknote Acceptor Integration Guide VARIOUS CASH BOX UNIT DIMENSIONS NOTE All Dimension are in Millimeters Figure 11 iVIZION Standard Cash Box Outside Dimensions NOTE Al...

Page 19: ...l support jcm germany com UK IRELAND JCM United Kingdom Ltd Phone 44 0 870 770 2863 Fax 44 0 190 837 7834 Unit B Third Avenue Denbigh West Business Park Bletchley Milton Keynes Buckinghamshire MK1 1EJ...

Page 20: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited 1 2 iVIZION Series Next Generation Banknote Acceptor Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...s and Telephone Numbers for 11 I Installation Processes for 4 iVIZION Unit photo of a 1 N Navigation within manual procedure for 1 S Safety pictographs indicating 1 to 3 symbols inside boxed area 1 Sp...

Page 22: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited 14 THIS PAGE INTENTIONALLY LEFT BLANK iVIZION Series IntegrationGuide INDEX...

Page 23: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited iVIZION Series IntegrationGuide INDEX...

Page 24: ...CONFIDENTIAL PROPERTY OF JCM GLOBAL DRAFT 5 2010 Japan CashMachine Co Limited iVIZION Series Integration Guide DRAFT RELEASE FOR OEM INTEGRATION USE ONLY...

Reviews: