SENSOR ON/OFF TEST
The Sensor ON/OFF Test verifies the operation of the TBV Sensors.
To test the Sensors, proceed as follows:
1. Click the
Sensor ON/OFF
a
).
2. Click the
“
Start
”
Screen Button.
3. Confirm that the
Sensor Timer running
text message appears (Figure 13
b
).
4. Verify the status of 17 Positioning Sensors (Figure 13
c
). If a Sensor is operating
properly, its status indicator (
Positioning Sensor
column) will change from
OFF
to
ON
or
ON
to
OFF
as the Sensor is blocked or unblocked.
5. Verify that the status of 28 Judgment Sensors (Figure 13
d
) appears as
OFF
.
If a Sensor is operating properly, its status indicator (
Judgment Sensor
column)
should appear
OFF
.
6. Disconnect electrical power from the TBV Unit.
7. Open the Validation Unit Cover (refer to Figure 3 on page 8).
8. Reapply Power to the TBV Unit.
9. Restart the JCM Tool Suite Standard Edition Software Application.
10.Click the
Service Mode
drop down menu, then select “
Performance Test
.”
NOTE: Status indicators for the following Sensors should always appear OFF:
ULL ORE
ULL NIR
ULL IR
URR ORE URR NIR
URR IR
NOTE: Refer to Table 12 on page 23 for the list of Sensor Names. Depending on
the TBV Model being tested, some Positioning Sensors may not be used.
a
b
c
d
Figure 13
Sensor ON/OFF Test Screen, Positioning & Judgment Sensors