© 2016 JCM American Corporation
2 6
October, 2016
TBV Transaction Based Validator
TBV ERROR CODE TABLES
This section identifies the Standard LED Error Codes for the TBV Unit. The
TBV Bezel LED will flash either
YELLOW,
GREEN
or
RED
when various
Error Conditions occur. Refer to Table 13 below for a list of TBV Banknote
Jam Error Codes and their solutions. The
LED Color Flash Sequence
column
indicates the number of times the Bezel LED flashes a particular color and the
corresponding Error. As an example, a single Yellow Flash indicates a
Banknote Jam Error at the Cash Box.
B
ANKNOTE
J
AM
E
RROR
C
ODES
Banknote Jams are indicated by the Bezel LED flashing a
YELLOW
color.
Count the number of Flashes between pauses to identify the Error, Causes and
Solutions.
Table 13
TBV Banknote Jam Error Codes
LED Color
Flash
Sequence
Error
Causes and Solutions
1
Banknote Jam
(Cash Box)
A Banknote jam is detected at the Cash Box.
[Solution] Check the Cash Box for a jammed Banknote.
[Relative Parts] Feed Motor, Stacker Sensor, Feed-Out Sensor
If the condition is not resolved, change the above related part or parts and
complete a Positioning Sensor Calibration procedure.
2
Banknote Jam
(Transport)
Sensors did not detect a Banknote present.
[Solution] Check for a jammed Banknote or foreign material. Check/clean all
Sensors.
[Relative Parts] Feed Motor, BNF Entrance Sensor, BNF Assignation
Sensor, Transport Entrance Sensor, Centering Sensor, Side Sensor,
Validation Sensor, Feed-Out Sensor
If the condition is not resolved, change the above related part or parts and
complete a full Calibration procedure.
3
Banknote
Chain
Sensors are blocked longer than specified.
[Solution] Check for a jammed Banknote or foreign material. Check/clean all
Sensors.
[Relative Parts] BNF Feed Roller, BNF Retard Roller, BNF Assignation
Sensor, Transport Entrance Sensor, Feed-Out Sensor
If the condition is not resolved, change the above related part or parts and
complete a full Calibration procedure.
4
Cash Box
Removed
Cash Box has been removed.
[Solution] Check that the Cash Box is seated properly.
[Relative Parts] Cash Box Sensor
If the condition is not resolved, change the above related part or parts.
5
Banknote
Transport Error
Sensors detected a Banknote with abnormal timing.
[Solution] Check for a jammed Banknote or foreign material. Check/clean all
Sensors.
[Relative Parts] Side Sensor, Validation Sensor, Feed-Out Sensor, Cash
Box Feed Out Sensor
If the condition is not resolved, change the above related part or parts and
complete a full Sensor Calibration procedure.