min
1. Place all the mixing system parts in a bin with a locally
approved food grade cleaning agent and hot water and soak
for approximately 20 minutes. (See Fig.1)
i
Note:
Use a pipe brush to clean the tubes.
Comply with the safety instructions and cleaning
instructions on the cleaning agent packaging.
The mixing system parts can also be washed in a
dishwasher.
1. Replace the filter and its cover. (See Fig.2)
2. Replace the mounting plate on the mixer motor and shaft.
Make sure to align the arrow on the whipper towards the flat
surface on the shaft. Press the whipper onto the shaft until it
“clicks” into position. (See Fig.3)
3. Turn the mounting plate clockwise until the mixer holes are
aligned to the 3 o’clock and 9 o’clock positions. Align the
guide hooks on the mixer bowl and insert them through the
plate and into the chassis (A). Finally, lock the mixer bowl in
by rotating the mounting plate clockwise until it completely
stops turning and the tab is at the Lock position (B). (See
Fig.4)
4. Replace the tube on the mixer bowl (C), and snap the outlet
nozzle on the mixing tray. Close the panel (E) and the
dispenser will automatically return to normal dispensing
functions. (See Fig.5)
5. The display will show
REINSTALL A CLEAN MIXING BOWL,
PRESS ENTER TO CONFIRM
. Press ENTER. (See Fig.6).
7- Cleaning
7.8 Cleaning the mixing system parts
7.9 Reassembling the mixing system
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
E
D
C
A
B
Fig.6