Chapter 5
Power meter, VFL (Visual Fault Locator) & Talkset
Talkset Function
User Manual
790000002/00
33
Talkset Function
The Talkset option enables two operators at opposite ends of an optical
link to communicate along the fiber. Each end of the optical link must be
provided with a 2000 Platform equipped with the Talkset option.
Talkset
configuration
The talkset configuration is set in the
System Settings
screen, in the
Channel
box (see
"Defining the Audio parameters of the 2000 Platform"
Connections
At each end of the fiber:
1
Connect the fiber to the Talkset port of the 2000 Platform, either
directly or through jumpers.
2
A headset (with earphones and a microphone) supplied with the
option may also be plugged into the 2000 Audio jack.
Establishing
communication
On the caller 2000 Platform, press the
H
OME
button, then validate the
Talkset
option:
n
NOTE
It is possible to use the talkset of the 2000 Platform and to carry out
measurements at the same time, on a different fiber.
JDSU recommends you to use the following connections:
- PC Fiber Connection (APC is not recommended)
- SC or FC connection (UPP is supplied but not recommended).
Fig. 15
Installation for Talkset use