background image

Using the Certifier40G 

41 

 

2.1.16 

How do I export result to Excel sheets or 

pdf reports? 

From the list of results, either click on the Excel icon of the 
PDF icon to generate the reports.  
 

 

Figure 28:  Reporter showing exporting results to PDF or Excel 

 

Or alternatively, you can click on the icons on the top right 
corner of the plot window to either export csv files or pdf 
reports. 
 

Summary of Contents for Certifier40G

Page 1: ...Table of Content 1 JDSU Certifier40G Cable Certification Tester www jdsu com go certifier40G...

Page 2: ...ting 14 1 11 Permanent Link Configuration Tests 14 1 12 Channel Configuration Tests 14 1 13 Certifier40G User Interface 15 1 13 1 Touch Screen Layout 15 1 13 2 The One Touch Concept 16 1 13 3 Key Icon...

Page 3: ...r40G to save results automatically 34 2 1 11 How do I add a new site in Certifier40G 35 2 1 12 Where do I change default labeling scheme for saving test results 36 2 1 13 What are the labeling options...

Page 4: ...7 Set Connector Information 51 3 8 Performing AutoTests 52 4 WEEE Directive Compliance 53 5 Customer Services and Warranty 54 5 1 Customer Service Standard Services 54 5 2 Technical Assistance 54 5 3...

Page 5: ...nd remote unit including Li Ion battery stylus w cord display cover 2 Carry Case 1 CAT6A permanent link interface adapter 2 CAT6A permanent link test cords 2 CAT6A channel adapter 2 1GB USB thumb driv...

Page 6: ...sec to turn off the unit This button also indicates the status of charging and remaining charge in the batteries of the device Refer to battery charging section for more information Touch Sensitive L...

Page 7: ...having to carry the device around to connect to a PC RJ 45 Connector Future Power Supply Jack Supply power and recharge the battery Note Only use the power adapter shipped with your Certifier40G Quick...

Page 8: ...remote unit with two CAT 6A channel adapters two CAT 6A link adapters and Class FA cable certification software license with pair of MM modules and pair of SM modules with NA Power Cord NGC 4500 FA EU...

Page 9: ...ion software license with UK Power Cord NGC 4500 MM UK Certifier40G Class FA and MM kit class FA adapters not included with UK Power Cord Certifier40G LAN cable certifier master unit remote unit with...

Page 10: ...coax adapters with 50 ohm and 75 ohm F type interface for testing frequency range of 1 3000 MHz in accordance with TIA 570B 568 C 4 NGC 4500 MM2 Certifier40G Multimode adapter pair Multimode Fiber ad...

Page 11: ...Channel Adapters The standard Certifier40G test kit NGC 4500 FA xx includes adapters for testing copper cabling in both Permanent Link and Channel Link configurations Permanent Link adapters connect...

Page 12: ...rds for performing certification Channel adapters connect to the customer s patch cords at the wall plate and telecommunications panel Certifier40G software compensates for the adapter s transmission...

Page 13: ...allations 1 9 Cabling Certification and Tests Certification testing with Certifier40G is intuitive and simple An autotest function coordinates a series of measurements between the local and remote dev...

Page 14: ...If not a permanent link test configuration is required Which standard should be used Category or Class 1 11Permanent Link Configuration Tests The permanent link configuration is used in facilities sti...

Page 15: ...Information Segment is the row at the top of the screen and provides Device Information Device Name Talk Set Status Storage and Battery information The Functionality Segment is below the information...

Page 16: ...test for various limits and cables that are to be certified c To manage data that is saved in the device to view saved results modify or delete the records d Perform troubleshooting and other functio...

Page 17: ...ou to set the system settings like Date Time Auto sleep Auto saving of results in the memory etc The last navigation tab in the setup section is information which provides information such as calibrat...

Page 18: ...nd results can be viewed and saved in this section Figure 6 Main Screen Figure 7 Detailed Results Figure 8 Plots 1 13 6 Data Selecting the DATA button allows you to manage site information the test re...

Page 19: ...eation time and edit results without using the PC based Reporter software 1 13 7 Tools The TOOLS button selects the tools area that lets you perform advanced troubleshooting using Certifier40G and per...

Page 20: ...Getting Started 20 Figure 10 Tools Screens...

Page 21: ...the adapters you are using the standard Certifier40G kit NGC 4500 FA xx contains everything needed to certify copper cabling up to Category 6A Class E using RJ45 connectors To certify using other copp...

Page 22: ...save plots with each test test result files are larger than if you omit plots Certifier40G allocates approximately 1 GB of internal Flash memory for test result storage The following table lists appro...

Page 23: ...hours before requiring recharging Reducing the screen brightness and enabling the sleep function allows Certifier40G to run longer on a charge 1 17 1 Using External Power 1 18 Battery Safety To avoid...

Page 24: ...es and seek medical attention Do not expose the battery pack to high storage temperatures above 55 C When discarding a battery pack contact your local waste disposal provider regarding local restricti...

Page 25: ...3 5mm stereo jack 1 21 Dimensions Size 232 mm x 126 mm x 86 7 mm 9 13 x 4 96 x 3 41 Weight approx 1 0 kg approx 2 2 lbs 1 22 Environmental Specifications Operating temperature 0 C to 40 C 32 F to 104...

Page 26: ...mware version information of my Certifier40G Go to SETUP and then select the Information tab to check the software version and hardware version numbers This screen also provides the next yearly calibr...

Page 27: ...27 2 1 2 How do I know if I have the correct adapter for testing The type of adapter that is installed in Certifier40G can be found from Test Settings tab in SETUP menu Figure 12 Information Screen s...

Page 28: ...Certifier40G Reporter software Plug in the USB flash drive in the USB host connector of Certifier40G local or remote unit this step must be repeated on both the local and remote unit Certifier40G wil...

Page 29: ...p date time in my Certifier40G From the SETUP one touch button go to System tab and select time and date It opens up the screens shown below Choose the editable button to set or change date and time F...

Page 30: ...uch button select the Test Settings tab Then choose Limit menu at the top and it will open up a screen with different limits to choose from Run through the hierarchy and choose the appropriate limit f...

Page 31: ...Test Setting Screen showing cable type selection To select the type of cable under certification go to Test Settings tab under SETUP one touch button It will open up a screen to select the cable manuf...

Page 32: ...quire you to perform a set reference measurement To perform a set reference measurement go to the TOOLS menu and select the set reference measurement icon Connect the Certifier40G local and remote uni...

Page 33: ...e the test is completed it will show the summary results page with Pass or Fail message Figure 18 Auto Test Certification Screens 2 1 9 How do I save test data Once the autotest is completed the test...

Page 34: ...e saved and press Save 2 1 10 How can I setup my Certifier40G to save results automatically Auto saving of results removes the hassle of manually having to save after every test You should setup the l...

Page 35: ...I add a new site in Certifier40G To add a new site for a certification job go to Setup one touch menu click the Site button and click on New a keypad will allow you to enter the site name Also enter...

Page 36: ...2 1 12 Where do I change default labeling scheme for saving test results From the SETUP one touch button under test settings select Label Source It will open up another screen with different types of...

Page 37: ...s Class 1 Class 2 and Class 3 labels See section 3 3 for details on setting up labeling options 2 1 14 How do I export test results into the Certifier40G Reporter Certifier40G Reporter is the PC based...

Page 38: ...ive how do I import from the PC Once the results are on the thumbdrive run the Reporter application from your PC desktop Please install Reporter SW as instructed in the Quick Start Guide Plug in the t...

Page 39: ...stored and click Create Project Once the project is created click on the file menu import test results to start the import process Figure 25 Reporter Screen showing importing results Choose the USB f...

Page 40: ...Using the Certifier40G 40 Figure 26 Reporter showing results from test You can view the desired plots by clicking on the respective labels of the test results Figure 27 Reporter showing plot data...

Page 41: ...From the list of results either click on the Excel icon of the PDF icon to generate the reports Figure 28 Reporter showing exporting results to PDF or Excel Or alternatively you can click on the icon...

Page 42: ...ative method for exporting results 2 1 17 Where can I change the Auto Power off time setting In the SETUP one touch button you can configure the Auto Power Off setting to the desired minute intervals...

Page 43: ...onstration demo mode If Certifier40G is in demonstration mode all the tests on Certifier40G are simulated tests and are not real To switch between Demo Mode or Real Testing mode go to SETUP one touch...

Page 44: ...l flash memory to the factory settings from the SETUP one touch button and System Settings screen Figure 32 Restoring Default Settings CAUTION Confirming this option will erase all current settings on...

Page 45: ...o remove the batteries 1 Turn the unit off and disconnect the external power supplies 2 Unscrew the flip battery compartment door and open it 3 Pull the battery out and insert a new battery and close...

Page 46: ...organizing the tests that are done under the site name you create The same site hierarchy is then displayed when exporting the results into the PC software Reporter 3 3 Choose the Labeling Format Cer...

Page 47: ...labels where the last character is incremented after every test Figure 33 Adding Simple Labels 3 3 2 TIA 606 A Class 1 Labels This type of labeling scheme follows the TIA 606 A Class 1 standard labeli...

Page 48: ...A 606 A Class 1 Labels 3 3 3 TIA 606A Class 2 This type of labeling scheme follows the TIA 606 A Class 2 standard labeling scheme It is mostly used to support Backbone to Telecom Room type installatio...

Page 49: ...el the reference point is the end of the test cord and the tester removes the effects of the permanent link cable to make sure the measurement only includes the permanent link Testing Copper Cables Tw...

Page 50: ...link configuration or channel link configuration testing 2 Insert matching adapters in the bays at the top of the units 3 Connect the adapters to the ends of the cable run being tested 3 4 1 Adapter I...

Page 51: ...right NVP for length measurements and make sure the correct cable type appears in the report See section 2 1 6 for selecting the cable type 3 7 Set Connector Information Selecting the correct connect...

Page 52: ...Detailed results can be viewed by pressing the DETAILS tab at the bottom which will display all the parameters that are measured during the test with the worst case margin displayed on the right most...

Page 53: ...all waste equipment and batteries returned are reused recycled or disposed of in an environmentally friendly manner and in compliance with all applicable national and international waste legislation I...

Page 54: ...air Calibration Services and Upgrade Services Immediate Return Authorizations 5 2 Technical Assistance Expert business hour technical support is included with your product Please reach the technical s...

Page 55: ...made by the user The type of application and the environmental conditions should be taken into account Contact a JDSU service center or customer service in your region regarding calibration 5 3 3 Fac...

Page 56: ...contacting JDSU Technical Assistance JDSU is not liable for any damage that may occur during shipping The customer should clearly mark the JDSU issued RA or reference number on the outside of the pac...

Page 57: ...Customer Services and Warranty 57 5 4 1 Warranty registration Please register your product at www jdsu com know register...

Page 58: ...Customer Services and Warranty 58 www jdsu com go certifier40G Document Information Doc 21159675 Revision 000 English...

Reviews: