GSM/GPRS/EDGE SIGNAL ANALYZER
26
JD7105B Base Station Analyzer
be inactive first to get the Limit hot key function other than the number input.
Step
Description
1.
Select the limit mode
LIMIT
[RF Test Limits]
[Occupied BW]
Press the
LIMIT
hot key. It is the number 7 key in the
numeric keypad.
Press the
RF Test Limits
soft key.
Press the
Occupied BW
soft key.
2.
Set the limit
[Test Limits]
<On>
or
<Off>
[High Limit]
Enter a value
[MHz]
,
[kHz]
, or
[Hz]
Press the
Test Limits
soft key to toggle between
On
and
Off
and select one.
Press the
High Limit
soft key to set the upper limit of the
Pass/Fail criteria. Use the numeric keys to input value.
Press the unit soft key to select.
3.
Enable beep
LIMIT
[Beep]
<On>
or
<Off>
Press the
LIMIT
hot key. It is the number 7 key in the
numeric keypad.
Press the
Beep
soft key to toggle between
On
and
Off
and select one. This will make audible alarm if the
measurement beyond the limit.
TEST LIMITS:
Enables or disables Pass/Fail results on the display screen. Toggle the
Test
Limits
soft key to select it to
On
or
Off
.
HIGH LIMIT:
Sets the upper limit of the Pass/Fail criteria. Use the numeric keys to enter a
threshold or limit value and press one of the unit soft keys to complete the input.