GSM/GPRS/EDGE SIGNAL ANALYZER
30
JD7105B Base Station Analyzer
Setting Limit
LIMIT
This hot key is used to set the threshold value for the limit line on the display screen. It turns on or off
the limit or band limit settings of the measurement for pass/fail indication. The user input window must
be inactive first to get the Limit hot key function other than the number input.
Step
Description
1.
Select the limit mode
LIMIT
[RF Test Limits]
[Spectrum Emission Mask]
Press the
LIMIT
hot key. It is the number 7 key in the
numeric keypad.
Press the
RF Test Limits
soft key.
Press the
Spectrum Emission Mask
soft key.
2.
Set the limit
[Test Limits]
<On>
or
<Off>
Press the
Test Limits
soft key to toggle between
On
and
Off
and select one.
3.
Enable beep
LIMIT
[Beep]
<On>
or
<Off>
Press the
LIMIT
hot key. It is the number 7 key in the
numeric keypad.
Press the
Beep
soft key to toggle between
On
and
Off
and select one. This will make audible alarm if the
measurement beyond the limit.
TEST LIMITS:
Enables or disables Pass/Fail results on the display screen. Toggle the
Test
Limits
soft key to select it to
On
or
Off
.