25
GSM/GPRS/EDGE SIGNAL ANALYZER
JD7105B Base Station Analyzer
O
CCUPIED
B
ANDWIDTH
It determines the frequency bandwidth that contains 99% of the total radiated power.
Measurement Procedure
Step
Description
1.
Connect the cable
Connect the cable to the
Spectrum Analyzer RF In 50
Ω
port of the JD7105B and the RF Output port of BTS.
2.
Set the measurement mode
MODE
[Signal Analyzer]
[GSM]
[RF Analysis]
[Occupied BW]
Press the
MODE
hard key.
Press the soft key to select the Signal Analyzer mode.
Press the
GSM
soft key.
Press the
RF Analysis
soft key.
Press the
Occupied BW
soft key.
3.
Set the measurement parameters
MEASURE SETUP
[Delay]
Enter a value
[uSec]
or
ENTER
[RX Filter]
[No Filter]
,
[100K]
,
[200K]
,
[400K (Default)]
, or
[624K]
Press the
MEASURE SETUP
hard key.
Press the
Delay
soft key to set the delay.
Use the numeric keys to input value.
Press the unit soft key or the
ENTER
hard key.
Press the
RX
Filter
soft key to select the internal RX filter
bandwidth among the choices.
GSM Occupied BW Measurement Procedure
MEASURE SETUP
DELAY:
Sets the delay in micro seconds. Use the numeric keys to input value and press the unit
soft key to complete the input.
RX FILTER:
Sets the internal RX filter bandwidth among
100K
,
200K
,
400K
, and
624K
. Default
setting is 400K.
Setting Limit
LIMIT
This hot key is used to set the threshold value for the limit line on the display screen. It turns on or off
the limit or band limit settings of the measurement for pass/fail indication. The user input window must