9
2. Apply optical grade isopropyl alcohol or optical grade ethanol (do not use rubbing alcohol) to
a small area of a lint-free towel and rub the end of the ferrule over the wet area.
3. Wipe the ferrule on a dry area of the lint-free towel.
4. Using the dusting gas or compressed air, blow the end of the ferrule.
5. Apply the alcohol or ethanol to a lint-free pipe cleaner or swab and wipe off the remaining
parts of the connector.
6. With the other end of the pipe cleaner or swab, dry the areas cleaned.
7. Using the dusting gas or compressed air, blow the areas cleaned.
Mounting Considerations
The SK switch can be mounted in any orientation. The optical fibers require sufficient clearance
to maintain a minimum bending radius of 1.5 cm. This clearance must be maintained around the
fiber exit area.
Power Interface Connector
All electrical connections (parallel interface and power) to the SK switch are made through a
standard 26-wire ribbon cable with an attached 26-pin, 0.254 cm (0.1 inch) dual row connector
(Figure 4).
Figure 4: Dual Row Connector
The pin assignment is listed in Table 4.