Commands 61
REPLACE
Command packet
Description
Replace output channel with factory spare
Parameters
Switch, Output, Spare
Parameter
Description
Switch (unsigned eight-bit)--switch number
Output (unsigned eight-bit)--channel number to be replaced
Spare (unsigned eight-bit)--factory spare number
OPCODE
Length
Parameters
0x33
0x3
U8 Switch, U8 Output, U8 Spare
Switch (unsigned eight-bit)--Logical switch number (1 to 4)
Output (unsigned eight-bit)--The replaced output channel (1 to 200)
Spare (unsigned eight-bit)--The factory spare number used for the replace-
ment (1 to 200)
This command resets the switch.
Summary of Contents for SKB Series
Page 1: ...SKB SERIES FIBEROPTIC SWITCH MODULE User Manual ...
Page 2: ...ii 10109002 Rev 001 August 2001 2001 JDS Uniphase All rights reserved ...
Page 4: ...iv ...
Page 11: ...7 Contents ...
Page 13: ...9 List of Figures ...
Page 15: ...11 List of Tables ...
Page 19: ...4 Safety Information Instructions and Symbols ...
Page 25: ...10 Introduction ...
Page 53: ...38 Operation and Control Instructions ...
Page 91: ...76 Commands ...
Page 111: ...96 Application Notes ...
Page 113: ...98 Service ...