36
36
Adressage & Etalognnage capteurs
Address & sensors Calibration
4.
• Automatic Printing :
If «Yes» automatic printout
at the end of the recording.
• Averaging (or smoothing) of the curve
a value too low will produce a very nervous plot,
a value too high will produce a very slow plot and
the details will be degraded.
A3 - Sensors
Adjustment of connected sensors
A3.1 - Setting
Paramétrage de la rotation et de l’inclinaison du mât
Tool Force
• Thrust
Off set :
• Thrust
Coeff
:
Mast inclination
Location of the inclination sensor IGHxx relative to
the mast.
A3.2 - Calibration
Settings of the diff erent sensors (zero, range of measurement, etc.)
Pin Time
Depth
Adjustment of the P82 sensor
•
Number of the layers on the winch,
•
For each layer enter the pulses number supplied
by the sensor by meter.
Tool Pressure
Adjustment of the pressure sensor (C16xx)
•
Zero : 4 mA generally
• Measuring
range
: 400 bar generally
• Automatic
calibration.
Rotation Speed
Adjustment of the rotation sensor (VR28)
•
Number of detected metallic studs, useful to
defi ne the rotation speed of the rotation table,
• Inhibition
time
Rotation Torque
Adjustment of the rotation torque sensor (C16xx)
•
Zero : 4 mA generally
• Measuring
range
: 400 bar generally
• Automatic
calibration.
Mast X Inclination
Adjustment of the inclination sensor (IGHxx)
• Zero
:
set X inclination sensor to zero when
the tool is perfectly vertical (the tool la kelly the
tool is down from 3 to 4 m in the excavation).
Use the keys «
+»
ou «–» for this adjustment.
Mast Y Inclination
Adjustment of the Y inclination sensor (IGHxx)
• Zero
: (same procedure as the X inclination).
Azimut machine
Adjustment of the orientation sensor (ORMA)
A3.3 - Address
Addressing of connected sensors to the connection box. Follow the same
procedure for each sensor