Adressage & Etalognnage capteurs
Address & sensors Calibration
4.
1
Use
: YES / NO
2
Module Origin
: name of this module in the connection box (MDIALH,
M8P ...).
3
Module Address Module
: each module has an address or ID. This is the
only way to have two identical modules on the same installation. Open
the connection box and check the number on the top right corner of the
module screen 5C, 6C. Or see the supplied wiring diagram.
4
Type
:
the sensor type most often used :
Analog
: for the pressure sensors(C16xxx)
Encoder
: for the depth and displacement sensors (F82, D90 ...)
Pulse
: for the rotation sensors (rpm/min), volume and flow
sensor, (l/mn)
Analog SC
: for pump strokes on the pressure.
5
Entry channel
: each screw terminal is defi ned by a number : indicate
connecteur à vis est défi nie par un numéro, you must indicate which
number a sensor has been connected.
A3.4 - Special
Registration, confi guration and activation of special sensors manufactured
by JEAN LUTZ SA.
RDS
Range of deviation sensors : PRAD - NEMO BT
- TAUPI ...
Basic setting
• Use,
• MAC
Address,
• Serial
Number
Advanced
•
Record Frequency :
•
Wake-Up Sensibility :
• Sleep
Time
:
•
Rotation sensibility :
•
Rotation Duration :
• Orientation
ANTOISE
GPS centimeter positioning sensor
(see annex for
details)
.